Owner Manual

GENERAL PUMP
A member of the Interpump Group
KFM SERIES
15.
TROUBLESHOOTING
The pump does not produce any noise at
start-up:
The pump is not primed and is running dry
There is no water in the inlet line
The valves are blocked
The delivery line is closed and does not allow
the air in the pump to be discharged
The pump pulses irregularly (knocking):
Air suction
Insufficient feeding
Bends, elbows, fittings along the suction line
obstruct the fluid’s passage
The inlet filter is dirty or too small
The booster pump, where provided, supplies
insufficient pressure or flow rate
The pump is not primed due to insufficient
head or the delivery line is closed during
priming
The pump is not primed due to valve seizing
Worn valves
Worn pressure packings
Incorrect operation of the pressure adjust
ment valve
Transmission problems
The pump does not deliver the rated flow / is
noisy:
Insufficient feeding (see the causes listed
above)
RPM are less than the rated flow
Excessive amount of water by-passed by the
pressure adjustment valve
Worn valves
Leakage from the pressure packings
Cavitation due to:
1) Wrong sizing of the suction hose/
undersized diameters
2) Insufficient flow rate
3) High water temperature
Insufficient pump pressure:
The nozzle (or has become)too large
Insufficient RPM
Leakage from the pressure packings
Incorrect operation of the pressure adjust-
ment valve
Worn valves
Page 14
Overheated pump:
The pump is overloaded (pressure or RPM
exceed the rated values)
Oil level is too low, or the oil is not of a suit
able type, indicated in Chapter 7 (see para
graph 7.4)
Incorrect alignment of the joint or pulleys
Excessive inclination of the pump during
operation
Pump vibrations or knocking:
Air suction
Incorrect operation of the pressure adjust
ment valve
Valve malfunction
Irregular drive transmission motion