Owner Manual User guide
GENERAL PUMP
A member of the Interpump Group
HF SERIES
Page 11
11. MAINTENANCE INSTRUCTIONS
11.1 Crank mechanism maintenance.
Check oil level at least on a weekly basis (Fig. 8).
If necessary, add the missing oil through the oil plug
(position 1, Fig. 8). Check oil level when the pump is at
room temperature. When changing the oil (removing the
plug position 3, Fig. 8), the pump should be at its work-
ing temperature.
Change oil every 1000 working hours, oil pump capacity
is 2 litres.
In any case the oil should be changed at least once
a year, since oxidation deteriorates it.
Mineral or synthetic oils can be used but they must be
chosen according to the working environment
temperature. Here below is a diagram indicating viscosity
according to room temperature.
List of recommended oils:
GENERAL PUMP
RECOMMENDS
USING SAE 50W
BRAND TYPE
GENERAL PUMP SERIES 220
ARAL Aral Degol BG220
BP ENERGOL HLP 220
CASTROL
Hyspin VG 220, Magna
220
ELF
POLYTELIS 220
ESSO NUTO 220
FINA Cirkan 220
FUCHS RENOLIN 220
MOBIL DTE OIL BB
SHELL TELLUS C 220
TEXACO RANDO HD 220
TOTAL CORTIS 220