User Manual

TSP Series “66”
GENERAL PUMPA member of the Interpump Group
TRIPLEX TRIPLEX
Triplex Plunger Pump
SERVICING INSTRUCTIONS
SERVICING PUMP PROCEDURES
General Pump
is a member of
the Interpump Group
8
Valve Replacement: All inlet and discharge valves can be serviced without disrupting the inlet or discharge
plumbing. The inlet and discharge valves are identical in all 66 TSF series models.
To service the valve assemblies:
1) Remove valve cap. Remove valve plug using 2, 4 mm x .7 mm
threaded bolts.
2) Remove outlet valve assembly from plug.
3) Remove plug to spacer O-ring.
Ref 300937 Rev. A