Gen-Eye POD™ & Gen-Eye MINI-POD™
Bad or Grainy Picture
Check the camera lens for dirt, grime, scratches or other foreign
matter.
Check the Light Head to see if it is not supplying sufficient light
due to weak, dirty, or burned out bulbs.
Check for external electrical noise being radiated by outside
sources, such as a power station, etc.
Check the push rod cable for possible breaks or intermittent open
circuits by flexing the cable.
Disconnect the main power source and contact the factory ser-
vice department.
General Wire Spring Co,
1101 Thompson Avenue
McKees Rocks, PA 15136
412-771-6300 www.drainbrain.com
© General Wire Spring Co. 2017
C-PODOI-0317
Monitor Not Responding to Remote Control:
Check whether batteries have sufficient power. Replace as
necessary.
Check whether batteries are correctly installed in remote con-
trol.
Check remote control sensor lens on monitor and distance/
angle of the remote control.
TROUBLESHOOTING CONTINUED