Brochure
Item Page
n
AutoCut 6
n
BD Drain Gun 57
n
ClogChopper 32
n
Closet Augers 54
n
Cold-Shot Pipe Freeze Kit 60
n
Cool Tools 60 – 63
n
Cutters 30 – 31
n
Cables for Electric Machines 33
n
D-25 Handy 52
n
Drain Augers, Hand Driven 57
n
Drain Gun 57
n
Drain-Rooter PH 9
n
Drum Augers 56
n
EasyReach 61
n
Flat Sewer Rods 59
n
Flexichain Cables 33
n
Flexicore Closet Augers 54
n
Flexicore Drain Augers 53
n
Flood-Guards 61
n
Flush Bags 59
n
Gen-Eye POD 44
n
Gen-Eye X-POD 45
n
Gen-Eye USB 46
n
Gen-Eye Micro-Scope 2 47
n
Gen-Ear LE 50 – 51
n
Handylectric 8
n
Hot-Shot Pipe Thawer 60
n
Hot-Spot Locator 48
n
Hot-Spot Transmitter 49
n
I-95 24
n
Jet-Set 32 – 43
n
Kinetic Water Ram 11
n
Little Mike 57
n
Maxi-Rooter 22 – 23
n
Micro-Rooter 57
n
Mini-Rooter Pro 12 – 13
n
Mini-Rooter XP 14 – 15
n
Model 88 26 – 27
n
Model DRZPH 10
n
Power-Vee 6 – 7
n
Proflex Cables 33
n
Rescue Wrap 63
n
Rodrunner 28
n
Rodrunner Model E Gas Powered 29
n
Root 66 25
n
Sewerooter T-4 16 – 17
n
Sectional Sewer Rods 58
n
Snake-Oil Plus 33
n
Speedrooter 92 18 – 19
n
Speedrooter XL 20 – 21
n
Spin-Drive 52
n
Spin-Thru 55
n
Super-Vee 4 – 5
n
SuperSlice 62
n
Test Plugs 59
n
Urinal Augers 55
n
VersaPlunge 63
n
Water Jets 34 – 35
General’s drain cleaning machines, Jet-Set water jets, Gen-Eye Micro-Scope,
Gen-Ear LE water leak locators, and Cold-Shot Pipe Freezing Kits carry a one year
limited warranty against defect or breakage except as noted below.
The Hot-Shot pipe thawing machines and all other Gen-Eye Pipe Inspection/Location
Systems carry a two year limited warranty (except the LCD Monitor and recording
device which are warranted for one year) against defect or breakage.
except as noted below. Should any part break or fail to work properly within the
warranty period following purchase, it will be repaired or replaced at our discretion
at no charge.
If a Flexicore
®
cable or Flexicore
®
Closet Auger should break during this period,
it too will be repaired or replaced at our expense, the choice to be made by us.
No adjustment can be made on kinked cables, since a kink is evidence of abuse
and results from the use of too much pressure or use in too large a line. Also, no
adjustment can be made where there is considerable wear at the point of the break,
or if a hand cable is used in a power machine.
Some parts, such as cutters, leaders, push rods, jet hoses, and nozzles, are subject
to severe wear and are repaired or replaced within one year only if a flaw in the
material causes breakage.
“G”, “L”, and “R” type sectional cables are covered by a 90 day warranty, in
accordance with the terms outlined above.
Damage due to negligence, rust, exposure to corrosive chemicals,
improper usage, failure to follow instructions, accidents, or alteration
from original design is not covered by this warranty.
In order to handle any adjustment with a minimum of delay, please follow
this procedure:
1. Return the part to your wholesaler, and have them notify us immediately with
complete information on the problem.
2. On power machines, we must have the serial number, the date of purchase,
and the name of the wholesaler from whom your machine was purchased.
To activate your machine warranty, your warranty card must be filled out and
sent to us immediately after your machine is purchased.
3. We will then advise your wholesaler if the part should be returned to us and
assign a return merchandise authorization (RMA) number. Ship freight prepaid,
and you will be compensated for these charges if it is determined that the part
is defective. If repairs are necessary due to conditions beyond our control,
or if the item is out of warranty, we will do the work at the lowest possible cost,
but a charge will be made.
This warranty is made in place of other warranties, expressed, statutory or implied,
including those of merchantability and of fitness for purpose. General shall not be
responsible for any incidental or consequential damages.
This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state. Some states do not allow the exclusion of limitation
of incidental or consequential damages, so these limitations may not apply to you.
1101 Thompson Avenue
McKees Rocks PA 15136 USA
www.drainbrain.com
General’s Limited Warranty & Index
For Use in Maximum
Typical Following Maximum Operating Recommended Motor
Applications Pipe Sizes Capacity Weight Distance Horsepower
Super-Vee
Power-Vee
35 ft. x 3/8" or
16 lbs. with
Handylectric
Sinks,
1-1/4" – 3"
50 ft. x 1/4" or 5/16"
25 ft. x 3/8"
50 ft.
3.2 amp
Pages 4 – 8
Bathtubs,
(30 mm x 75 mm)
(10.5 m x 9.5 mm)
(7 kg)
(15 m)
Drain-Rooter PH
Roofstacks
(15 m x 7.9 mm)
Page 9
34 lbs. (15 kg)
DRZ-PH
Page 10
30 lbs. (13 kg)
1/5 hp
Mini-Rooter Pro
Small Drains,
2"– 3" and most 4"
75 ft. x 1/2" or 3/8"
62 lbs
.
75 ft.
1/3 hp
Pages 12 – 13
Inside Work,
(30 mm – 100 mm)
(22.5 m x 12.7 mm)
With 75 ft. x 3/8"
(22.5 m)
On Roofs
(Not For Roots)
(28 kg)
Small Drains,
2"– 3" and most 4"
75 ft. x 1/2" or 3/8"
92 lbs.
75 ft.
Mini-Rooter XP Inside Work,
(30 mm – 100 mm)
(22.5 m x 12.7 mm)
With 75 ft. x 3/8"
(22.5 m)
1/3 hp
Pages 14 – 15
On Roofs
(Not For Roots)
(42 kg)
Small Drains
100 ft. x 9/16"
Sewerooter T-4
with 9/16" cable;
3" – 6"
75 ft x 5/8"
158 lbs
150 ft
Pages 16 – 17
Roots with
(75 mm – 150 mm)
(30 m x 14.2 mm)
(72 kg)
(45 m)
1/3 hp
5/8" cable
(22.5 m x 15.8 mm)
Speedrooter 92
Main lines, Roots, 3" – 10" 100 ft. x 5/8"or 3/4" 220 lbs. 200 ft. 1/2 hp
Pages 18 – 19
Difficult Obstructions (75 mm – 250 mm) (30 m x 15.8 or 19 mm) (100 kg) (60 m)
(Optional 3/4 hp)
Main Lines,
roots with 5/8"or
100 ft. x 3/4"
Speedrooter XL
3/4" cable;
3" –10"
5/8" or 1/2"
220 lbs 200 ft.
Pages 20 – 21
Small drains with
(75 mm – 250 mm)
(30 m x 19)
(100 kg) (60 m)
3/4 hp
1/2" cable
(15.8 or 12.7 mm)
Main Lines, Roots,
125 ft. x 3/4"
Maxi-Rooter
Diffi
cult
3" – 10"
150 ft. x 5/8"
250 lbs.
200 ft.
Page 22 – 23
Obstructions
(75 mm – 250 mm)
(37.5 m x 19 mm)
114 kg
(60 m)
3/4 hp
(45 m x 15.8 mm)
Small Drains
1-1/4" – 4"
125 ft. x 5/8" cable
I-95
Inside Work,
(30 mm – 100 mm)
Not
42 lbs.
150 ft. x 7/8" cable
1/3 hp
Page 24
On Roofs
(Not For Roots)
Applicable
Without Sections
(38 m x 15.8 mm) Optional 1/2 hp
(45 m x 22.4 mm)
125 ft. x 5/8" cable
Small Drains,
1-1/4" – 4" Not
42 lbs.
150 ft. x 7/8" cable
Root 66 Inside Work (30 mm – 100 mm) Applicable Without Sections
(38 m x 15.8 mm)
1/2 hp
Page 25
On Roofs
(19 kg)
(45 m x 22.4 mm)
Model 88
Main Lines, Roots
3" – 10"
Not
80 lbs
200 ft.
Pages 26 – 27
(75 mm – 250 mm)
Applicable
Without Sections
(60 m)
3/4 hp
Difficult Obstructions
(36 kg)
90 lbs
Rodrunner
Main Lines, Roots
3" – 10"
Not
Without Sections
200 ft. – (60 m)
3/4 hp
Page 28
Difficult Obstructions
(75 mm – 250 mm)
Applicable
(41 kg)
300 ft. – (90 m)
Rodrunner Model E
Main Lines, Roots 3" – 10" Not
185 lbs.
Difficult Obstructions (75 mm – 250 mm) Applicable
Without Sections
500 ft. – (150 m)
6.5 hp Gas Engine
Page 29
(84 kg)
Jet-Set
1/2" hose – 4" thru 12"
400 ft. x 1/2"
1900 lbs. (862 kg)
400 ft. x 1/2" hose
24 hp Gas Engine
JM-2512
(100 mm x 300 mm) (120 m x 12.7 mm)
JM-3080 Grease, Sand, 3/8" hose – 4" thru 8"
300 ft. x 3/8" 375 lbs. (170 kg) 300 ft. x 3/8" hose 20 hp Gas Engine
JM-3055
Soft Stoppages,
(100 mm x 300 mm)
300 ft. x 3/8"
299 lbs. (135 kg) (90 m x 9.5 mm) 16 hp Gas Engine
JM-3000 and Ice 1/4" hose – 2" thru 4" 300 ft. x 3/8" 291 lbs. (132 kg) 200 ft. x 1/4" hose 13 hp Gas Engine
JM-2900 (50 mm x 100 mm) 200 ft. x 3/8" 180 lbs. (82 kg) (60 m x 6.4 mm) 13 hp Gas Engine
JM-1450 1/8" hose – 1-1/2" thru 2" 150 ft. x 1/4" 111 lbs. (50 kg) 75 ft. x 1/8" hose 1.5 hp 13 amp
JM-1000 (38 mm x 50 mm) 75 ft. x 1/8" 22 lbs. (10 kg) (22.5 m x 3.2 mm) 1.2 hp 13 amp
Power Drain Cleaner Comparison Chart
n
Use 1/4" Cable in 1-1/4" – 2" Lines
n
5/16" Cable in 1-1/2" – 2" Lines
n
3/8" Cable in 2" – 3" Lines
n
1/2" and 9/16" Cable in 3" – 4" Lines (Not Roots)
n
5/8" Cable in 3" – 6" Lines
n
3/4" Cable in 4" – 10" Lines
n
5/8" Sectional in 1-1/4" – 3" Lines
n
7/8" Sectional in 2" – 4" Lines
n
1-1/4" Sectional in 3" – 10" Lines