Instruction Manual

Page 25 of 43
General Machine Products Co., Inc.
In-Feed
Out-Feed
Cable Guide Set 32875
In-Feed
Guide Insert
Set - 32877
14. Blown Fiber Conversion (1.1mm, 1.6mm and 2.0mm) with 5mm Micro Duct
Micro Duct
Seal
89549 5/pk
Seal Guide
Half Set
32876
Optional
Split Cable Guide
1.1mm 33090
1.6mm 33091
2.0mm 33426
Air Box
Assy
32879
Duct Clamp
Set
32874
Parts required for a 12
count blown fiber conver-
sion are available in a kit
form.
Blowing Tips:
Insert a 2” piece of
5mm tubing in the In-
Feed Clamp Assy.
The measuring fixed
roller should be ad-
justed so that just
enough pressure is on
the fiber to turn the
measuring wheel with-
out deflecting it.
Set the tube in the air
box as shown in photo
to right. This prevents
possible buckling of
the fiber in the air box.
Feed the fiber along
the guides and into
the tube, making sure
that the fiber is cen-
tered in the guides be-
fore you close the air
box.
Ensure that the fiber
feeds freely through
the Breeze and into the
tube manually before
setting the drive rollers.
In-Feed
Guide set
32878
Solid Cable Guide
1.1mm 33087
1.6mm 33043
2.0mm 33425
Note: Cable guide must be inserted
against the air box to insure clear-
ance for the rollers. Failure to do
so will result in damage to the
drive wheels.
Drive Wheel Set
(Not Shown)
89589