User's Manual

3-10
Table 3-3. Remote Transceiver Operation Commands (Cont)
CODE NAME DESCRIPTION
EQUIVALENT
TRANSCEIVER
KEYPAD COMMAND
R
Note 1
Receive Frequency The "R" Command sets the receive frequency
value for the current preset channel.
The “R” Command followed by 6 digits will
define a receive frequency value. The 7
th
digit
is automatically determined by the transceiver.
The ‘x’ values, along with the 7
th
digit, must be
divisible by 25 kHz, 12.5 kHz, or 5 kHz.
"Rxxxxxx" = receive frequency
Transceivers with the EBN-30 Option, for the
30-90 MHz band, the first digit following the “R”
Command will be a "0" which is then followed
by 5 digits to define the receive frequency
value. The 7
th
digit is automatically determined
by the transceiver. The ‘x’ values, along with
the 7
th
digit, must be divisible by 25 kHz or 12.5
kHz.
“R0xxxxx” = receive frequency for the 30-90
Band
Transceivers with the EBN-400 Option, for the
400-420 MHz band, the first digit following the
“R” Command will be a "4" which is then
followed by 5 digits to define the receive
frequency value. The 7
th
digit is automatically
determined by the transceiver. The ‘x’ values,
along with the 7
th
digit, must be divisible by
25 kHz, 12.5 kHz, or 5 kHz.
“R4xxxxx” = receive frequency for the 400-420
Band
BCN
1
FREQ
0 - 9
XXX
(ENTER 6 DIGITS)
Note: When using the
keypad to input the
receive frequency, the
transmit frequency is also
entered simultaneously.
(See Paragraph 2-3.2.2)