Installation Manual
DRAFT COPY
NOMAD MXU Installation Manual
3:36 PM 02/12/99
DRAFT COPY
25
APPENDIX “A” –User Site, Pre Installation Check List
PURPOSE: The purpose of this checklist is to prevent problems during the installation phase. This
checklist is not an installation guide, it should be completed before the NOMAD MXU equipment arrives
on site. Figure A1 below is a summary of the checklist.
Typical User MXU Installation.
NOMAD MXU CONSOLE
Check 1: Determine the environment of the NOMAD MXU console will be
+15
o
C to +35
o
C and a maximum 80% relative humidity , non-condensing. ______
ANTENNAS
Check 2: Location of Antennas
Clear line of sight, Horizon to Horizon___________________________________
Check 3: Verify an 8 meter outside antenna coax (W1) is of sufficient length___________
If the length is not sufficient, see Appendix “B”.
Check 4: Verify 1.5 meter inside antenna coax (W2) is of sufficient length_____________
If the length is not sufficient, see Appendix “B”
PSTN
Check 5, Verify local PSTN Connections will accept PJ11 type plugs_________________
Cables supplied with the MXU, have RJ11 plugs on each end.
If the PSTN receptacles are not RJ11 types, adapters have to be procured by the user.
Check 6: Verify all four sets of phone lines are 2 wire analog_________________________
Line 1
Line 2
Line 3
Line 4
Channe l 1
Channel 2
Channe l 3
On
Ready
Power
Channel 1
Initiate
Power
Down
Sequenc e
Control Interface
Example:
110VAC
50/60 HZ
, Null Modem Cable
(RS232, Customer Furnished)
Power Cord
Check 1:
Determine location of the console
(+15 C to +35 C, Max 80% Relative Humidity, Non-Condensing)
Check 2:
Determine location of the antennas
( Clear Line of Sight, Horizon to Horizon)
Check 3:
Length of Outside Antenna Coax
Check 4:
Length of Inside Coax
Check 5,
Type of PSTN Connectors (RJ11)
Check 6,
Verify phone lines are 2 wire analog
Check 7,
Verify phone line with Modem call to Gateway
Check 10
, Verify correct power cord has been ordered.
Check 11
, Monitor Station Requirements
To
Local
PSTN
NOMAD
Console
Lighting
Arrestors
Lighting Rod
Monitor
Station
Check 8:
Verify correct power
Check 9:
Verify power outlet is grounded
Check 12,
Null Modem Cable available
o
o