Node B Installation Guide
DRAFT
17 July, 2001 IPWireless Proprietary
IT IS ILLEGAL TO MAKE COPIES OF THIS DOCUMENT WITHOUT EXPRESS PERMISSION BY IPWIRELESS
20
The conduits must be fixed to the brackets prior to fixing the bracket to the wall.
Leave a sufficient loop of cables to enable them to be prep’d back to the appropriate length.
The following figure specifies the way the conduit bracket glands have been designated
signifying which cables should be fed thru which gland.
The glands and conduit should be fitted to the mount bracket prior to the NodeB being mounted
onto to the mounting bracket.
The cable should be fed thru the glands and the glands ‘sealed’ prior to the NodeB being
mounted onto to the mounting bracket. Excess cable should be fed thru.
The cables should be secured to the conduit bracket strain relief.
Looped
Cable
Power
T1 x 2
T1 x 2
or
Ethernet x1
L
N
A
Al
a
rm
s