LINE DIAGRAMS PWR CELL

- 1 PWRcell Inverter - 1 CT Kit (included)
- 3 PV Links (max. 6)
- 1 PWRcell Battery
This design shows a PWRcell system with a Protected
Loads panel to provide backup power to loads. This design
uses the sum rule approach for the load-side connection of an
energy storage system.
This configuration is for use with 100A utility services.
30A
30A
30A
30A
Power Conversion
PWRcell
TM
Inverter
Generac
PowerCore
Router
Ethernet (CAT5)
50A
AC Grid
Main Service
Panel
Protected Loads Panel
CTs (CAT5)
M
100A
40A 60A
Loads Panel
Storage
PWRcell Battery
PV Array
PV Optimization
PV Link
TM
Substring Optimizer
REbus
TM
DC nanogrid
Powered by REbus (DC Voltage)
AC Voltage
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION.
*Installer responsible for code compliance.
*Refer to product manuals for additional installation
details and requirements.
100A Residential Service / Solar + Storage
Reference Code-131E-01
Part No. A0000521683 | Rev. F | 25 FEB 2021