Manual
Model # ............................................................... 005797-0, 005798-0
RatedMax. Power................................................................... 7.0 kW**
Surge Power............................................................................. 8.75 kW
RatedACVoltage...................................................................... 120/240
RatedMax ACLoad
Current @ 240V............................................................. 29.2 Amps**
Current @ 120V............................................................. 58.3 Amps**
RatedFrequency.................................................... 60 Hz@ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
BatteryType.................................................................... 10 AH, 12VDC
Model # ................................................................................ 885796-0
RatedMax. Power................................................................... 6.5 kW**
Surge Power............................................................................. 8.13 kW
RatedACVoltage...................................................................... 120/240
RatedMax ACLoad
Current@ 240V............................................................. 27.1 Amps**
Current@ 120V............................................................. 54.2 Amps**
RatedFrequency.................................................... 60 Hz@ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
** Maximumwattageandcurrentaresubjectto,andlimitedby,suchfactors
asfuelBtucontent,ambienttemperature,altitude,enginecondition,etc..
Maximumpowerdecreasesabout3.5%for each1,000feetabovesealevel;
andwillalsodecreaseabout1%for each6° C (10° F)above16° C(60° F)
ambienttemperature.
3.2.2 ENGINESPECIFICAtiONS
RatedHorsepower@ 3600 RPM.................................................... 14.5
Displacement............................................................................... 410cc
SparkPlugType................................... ChampionRO14YOor Equivalent
SparkPlug Gap............................................... 0.030 inch or (0.76 mm)
GasolineCapacity............................................................ 9 U.S. gallons
OilType.................................... SeeChart in "AddingEngineOil"Section
OilCapacity................................................ w/Filter Change= 1.5 Qts.
w/o FilterChange= 1.2 Qts.
Run Time/FuelConsumption-l/2 Load .. 10 Hours/ .73 gallons per hour
ClassI1EmissionCertified
3.2.3 EM/SS/ONS/NFORMATiON
The Environmental Protection Agency (EPA) and California Air
Resource Board (CARB)requirethat your generator comply with
exhaust and evaporative emission standards. This generator is
certified to meet the applicable EPAand CARB emission levels.
Additional information regardingthe requirementsset by EPAand
CARBis as follows:
It is important that you follow the maintenance specifications
provided in this manualto ensurethat your enginecomplies with
the applicableemission standardsfor the durationof the engine's
life. This engine is certified to operateon gasoline.The emission
control system on your generatorconsists of the following:
* FuelSystem * Air Induction System
FuelTank - Intakepipe/manifold
FuelCap - Aircleaner
Carburetor • IgnitionSystem
FuelLines - Spark plug
* EvaporativeControl System - Ignitionmodule
CarbonCanister * ExhaustSystem
VaporHoses _ PulseAir InjectionValve
Muffler
The Emissions Compliance Period referred to on the Emissions
Compliance Label indicates the number of operating hours for
which the enginehas been shown to meet Federaland California
emission requirements. See the table below to determine the
compliance period for your generator.The displacement of your
generatoris listed onthe EmissionsComplianceLabel.
Displacement Category CompliancePeriod
A 500 Hours
_>66 cc- < 225 cc B 250 Hours
C 125 Hours
A 1000 Hours
_>225 cc B 500 Hours
C 250 Hours
3.3 GENERALRECOMMENDATIONS
Thewarranty of the generatordoes notcover itemsthat havebeen
subjected to operator abuse or negligence.To receivefull value
from the warranty, the operator must maintain the generator as
instructed inthis manual.
Some adjustments wilt need to be made periodically to properly
maintainthe generator.
All adjustments in the Maintenancesectionof this manual should
be madeat leastonce eachseason.Followthe requirementsinthe
"MaintenanceSchedule".
NOTE:
Oncea year replace the spark plug and replace the air filter.
A new spark plug and clean air filter assure proper fuel-air
mixture and help the engine run better and lastlonger.
3.3.1 GENERATORMAINTENANCE
Generatormaintenanceconsists of keepingthe unitclean and dry.
Operateand storethe unit in a cleandry environmentwhere it will
not be exposedto excessivedust,dirt, moisture or any corrosive
vapors.Coolingair slots in the generatormust not becomeclogged
with snow, leaves,or any otherforeign material.
Checkthe cleanlinessof the generatorfrequently and clean when
dust, dirt, oil, moisture or other foreign substances arevisible on
its exteriorsurface.
,&CAUTION!
,_ Never insertany object or toolthroughthe air cooling
slots, even if the engine is notrunning.
12