2.8.1 ELECTRICSTARtiNG(XG7OOOE& XGSOOOE)
• Tostart the engine,pressandhold the Start/Run/Stopswitch in
the "Start" position. The enginewill crankand attemptto start.
Whenthe enginestarts, releasetheswitch to the run position.
• When the engine starts, push choke knob to "1/2 Choke"
position until the engine runs smoothly andthen fully in to the
"Run" position. If enginefalters, pull choke knob back out to
"1/2 Choke" position until the engine runs smoothly and then
to "Run" position.
• This generator is also equippedwith a manual recoil starter
which may be usedif the battery is discharged.
NOTE:
The engineStart/Run/Stop switch mustbe in the RUN
position when usingthe manualrecoil starter.
2.9 STOPPINGTHEENGINE
* Shutoff all loads,then unplugthe electricalloadsfrom generator
panelreceptacles.Neverstart or stop theenginewith electrical
devices pluggedin andturned on.
* Let engine run at no-load for several minutes to stabilize the
internaltemperaturesof engineandgenerator.
, Move Start/Run/Stopor On/Offswitch to the "Off" position.
* Closefuel valve.
2.10LOWOILPRESSURESHUTDOWNSYSTEM
The engineis equippedwith a low oil pressuresensor that shuts
down the engineautomaticallywhenthe oil pressuredrops below
5 psi. A delay built into the low oil shutdown system allows oil
pressureto build during starting. The delay allows the engineto
run for about 10 secondsbeforesensingoil pressure.If the engine
shuts down by itself andthe fuel tank has enoughgasoline,check
engineoil level.
2.10.1RESTARtiNG
Iftrying to restartthe enginewithin 10seconds afterit shutsdown,
the enginemay NOTstart. The system needs5 to 10 secondsto
reset.
If the engine is restarted after such a shutdown and the low oil
pressurehas not beencorrected,the enginewill run for about 10
seconds as describedabove andthen stop.
2.11CHARGINGTHEBATTERY(XGTOOOE&XG8OOOE)
Do not permit smoking, open flame, sparks
or any other source of heat around a battery.
Wear protective goggles, rubber apron and
rubber gloves when working around a battery.
Battery electrolyte fluid is an extremely
corrosive sulfuric acid solution that can cause
severe burns, if spill occurs flush area with
clear water immediately.
Storage batteries give off explosive hydrogen
gas while recharging. An explosive mixture will
remain around the battery for a long time after
it has been charged. The slightest spark can
ignite the hydrogen and cause an explosion.
Such an explosion can shatter the battery and
cause blindness or other serious injury.
Use batterychargerplugto keepthe battery chargedand ready
for use. Batterychargingshould be done in a dry location.
1. Plugcharger into "Battery ChargerInput" jack, locatedon the
control panel.Plugwall receptacleend of the battery charger
into a 120 Volt AC wall outlet.
2. Unplugbattery chargerfrom wall outlet andcontrol paneljack
when generatoris goingto be in use.
NOTE:
Do not use the battery chargerfor more than 48 hoursat one
charge.
3.1 MAINTENANCESCHEDULE
Follow the calendar intervals. More frequent service is required
when operatingin adverseconditions noted below.
CheckOil Level
ChangeOil and OilFilter:!:
CleanSparkArrestor Screen
ServiceAir Cleaner
ReplaceSpark Plug
$
"k
At Each Use
*Every Season/Every100 Hours
*Every Season/Every100 Hours
**Every Season/Every200 Hours
EverySeason
Changeoil after first 30 hours of operationthen every season.
Changeoil and oil filter every month when operating underheavy load or in
high temperatures.
Clean more often under dirty or dusty operating conditions. Replace air
cleanerparts if very dirty.
3.2 PRODUCTSPECIFICATIONS
3.2.1 GENERATORSPEC/F/CATIONS
Model # ............................................................... 005800-0, 005747-0
RatedMax. Power................................................................... 8.0 kW**
Surge Power................................................................................ 10 kW
RatedACVoltage...................................................................... 120/240
RatedMax AC Load
Current @ 240V............................................................. 33.3 Amps**
Current @ 120V............................................................. 66.7 Amps**
RatedFrequency.................................................... 60 Hz@ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
BatteryType.................................................................... 10 AH, 12VDC
11