100-200 Amps CSA Approved Service Rated Transfer Switches
All Timing and sensing functions originate in the generator controller
Utility voltage drop-out ......................................................................................................................................................................................................................<60%
Timer to generator start ...................................................................................................................................... 10 second factory set, adjustable between 10-30 seconds
Engine warm up delay ................................................................................................................................................................................................................. 5 seconds
Standby voltage sensor ..................................................................................................................................................................................................60% for 5 seconds
Utility voltage pickup .........................................................................................................................................................................................................................>80%
Re-transfer time delay ...............................................................................................................................................................................................................15 seconds
Engine cool-down timer ............................................................................................................................................................................................................60 seconds
Exerciser .............................................................................................................................................................................................................. 12 minutes every 7 days
The transfer switch can be operated manually without power applied.
Electrically operated, mechanically-held contacts for fast, positive
connections.
Rated for all classes of load, 100% equipment rated, both inductive and
resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 3R (indoor/outdoor rated) aluminum enclosure is standard.
Specifications
Features
Amps 100 200
External Dimensions
Height Width
Depth
Height Width
Depth
H1 H2 W1 W2 H1 H2 W1 W2
Inches 16.3 20.2 11.8 14.6 7.1 26 30 12.5 16 7.1
mm 414 513.1 299.7 370.8 180.3 660.4 762 317.5 406.4 180.3
Unit Weight – lbs.
kilos
21
9.53
38.5
17.46
Model RTSE100A3CSA RTSE200A3CSA
Amps 100 200
Voltage 120/240, 1ø 120/240, 1ø
Load Transition Type
(Automatic)
Open Transition
Service Rated
Open Transition
Service Rated
Enclosure Type NEMA 3R NEMA 3R
Withstand Rating
(Amps) 10,000 22,000
Lug Range 2/0 - #14 400 MCM - #4
H2
DEPTH
H1
W2
W1
H2
DEPTH
H1
W2
W1
100 Amp Switch
200 Amp Switch
100-200 Amps