100 Amp, Single Phase, 16 Circuit Limited Circuit Switches
®
All timing and sensing functions originate in the generator controller
Utility voltage drop-out ......................................................................................................................................................................................................................<60%
Timer to generator start ..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer*
Engine warm up delay ................................................................................................................................................................................................................. 5 seconds
Standby voltage sensor ..................................................................................................................................................................................................60% for 5 seconds
Utility voltage pickup .........................................................................................................................................................................................................................>80%
Re-transfer time delay ...............................................................................................................................................................................................................15 seconds
Engine cool-down timer ............................................................................................................................................................................................................60 seconds
Exerciser .............................................................................................................................................................................................................. 12 minutes every 7 days
Auxiliary lock out contact ...............................................................................................................................Lock out a single load or annunciate generator transfer status
The transfer switch can be operated manually without power applied.
*When used in conjunction with units utilizing Evolution™ controls
Specifications
H2
DEPTH
H1
W2
W1
Model
RTG16EZA3
Height
(in./mm)
H1 26.75/679.4
H2 30.1/764.3
Width
(in./mm)
W1 10.5/266.7
W2 13.5/341.8
Depth (in./mm) 6.91/175.4
Weight (lbs./kilos) 39/17.69
Model RTG16EZA3
Amps 100
Voltage 120/240, 1ø
Load Transition Type (Automatic) Open Transition
Enclosure Type NEMA 3R
UL Rating UL/CUL
Withstand Rating (Amps) 10,000
Lug Range 1/0 - #14
UPC Code 696471618792
Limited Circuit Switch