Use and Care Manual
010060
C
B
A
Maintenance
Owner’s Manual for Spark-Ignited Stationary Generators 31
Figure 5-11. Check Accessory/Drive Belt Deflection
A Water pump pulley
B Alternator pulley
C Automatic tensioner
Replacing Air Filter Element
Proceed as follows to replace air filter element:
1. See Figure 5-12. Remove nut (B) and bolt (C) from
air filter clamp, and loosen elbow clamp (D) to
r
elease air cleaner.
010162
B
C
D
A
Figure 5-12. Air Cleaner Cover and Filter Element
2. Remove air filter eleme
nt (A) and discard.
3. Th
oroughly clean elbow of any dust, dirt, or debris.
4. Place ne
w air filter element into elbow clamp.
5. In
stall elbow clamp over clamping surfaces and
tighten. Install nut and bolt from air filter clamp, and
tighten until snug.
NOTE: Service k
its are available from an IASD.
Final Instructions
Proceed as follows if only performing Schedule A mainte-
nance procedures:
1. Insta
ll negative battery cable (black) onto negative
battery (-) terminal.
2. Inst
all left and right side access panels. See
Access Panels.
3. See Return To Service.