Product Manual
2.4L5.4L1.5L
FULL
A
B
C
Maintenance
Owner’s Manual for Stationary Generators 35
Figure 5-7. Oil Level Dipstick and Oil Fill Cap
Replace Lubricating Oil and Oil Filter
NOTE: On 36 kW, 45 kW, and 60 kW models, close
shutoff valve to avoid draining the oil supply tank with the
crankcase oil. For more information, see Lube Oil
Maintainer System.
1. Remove oil drain hose from holding clamp (A). See
Figu
re 5-8.
2. Use one wrench to hold hex on hose fitting (to
pr
event rotation), and use second wrench to
remove drain plug.
(000139)
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
(000210)
WARNING
Skin irritation. Avoid prolonged or repeated contact with
used motor oil. Used motor oil has been shown to cause
skin cancer in laboratory animals. Thoroughly wash
exposed areas with soap and water.
3. Drain oil into a suitable container.
4. Install drain plug onto end of oil drain hose.
5. Install oil drain hose into holding clamp.
6. Rotate o
il filter counterclockwise to remove from oil
filter adapter (B). See Figure 5-8.
7. Apply a light coat of clean engine oil to gasket of
ne
w oil filter.
8. Install oil filter by hand until gasket just contacts oil
filt
er adapter. Tighten oil filter an additional 3/4 to
one full turn.
9. Remove fill cap and fill engine with the
r
ecommended quantity and type of oil. See Engine
Oil Recommendations. Crankcase oil capacity is
listed below:
Lubrication System Capacity (Oil Pan Including Oil Filter)
Model 22/27 kW 25-30 kW 32/38 kW 36/45 kW 48 kW 60 kW
Engine 2.4L 1.5L 2.4L 2.4L 5.4L 2.4L
4.0 quarts (3.8 liters)
• • • •
6.0 quarts (5.7 liters)
•
5.25 quarts (5 liters)
•
10. Install fill cap.
11. Install negative battery cable
(black) onto negative
(-) battery terminal.
12. Pull up rubber flap covering fuse holder and install
7.5 a
mp fuse.