Spec Sheet

MMG55DF4 | 2.9 L | 55kVA
MOBILE DIESEL GENERATOR SET
EPA Emissions Certification: Final Tier 4
SPEC SHEET
5 of 6
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Mobile Authorized Service Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, ISO8665, ISO3046, SAE
J1228, SAE J1995, and DIN6271 standards.
POWER RATINGS
Standby: kW/kVA (A) Prime: kW/kVA (A)
1-phase, 120/240 VAC @ 1.0 pf* 46/46 (192) 42/42 (175)
3-phase, 120/208 VAC @ 0.8 pf 48/60 (167) 44/55 (153)
3-phase, 120/240 VAC @ 0.8 pf** 48/60 (144) 45/55 (132)
3-phase, 277/480 VAC @ 0.8 pf 48/60 (72) 45/55 (66)
*Alternator limited.
**Power ratings achieved through use of optional 4-position phase switch.
FUEL CONSUMPTION RATES
Load Fuel: gph (Lph)
Standby Prime
50% NA 2.3 (8.7)
75% NA 3.2 (12.1)
100% NA 3.9 (14.8)
OPERATING DATA