Product Manual
Table Of Contents
- Table of Contents
- Safety
- General Information
- Specifications
- Unit Serial Number Locations
- Component Locations
- Control Panel
- Power Zone™ Gen Controller
- Controller Features and Functions
- Operator Screens
- Alarm Mute
- Auto/Manual Mode
- Navigation Buttons
- Control Power Switch
- Engine Start
- Engine Stop/Reset
- The Liquid Crystal Display (LCD)
- Operator Screens
- Home Screen
- Engine Screen
- Generator Screen
- Voltage Adjust Screen
- Maintenance Screens
- Generator Summary
- Engine Tab
- Generator Tab
- Alarms Tab
- Input/Output Tab
- Schedule Tab
- Status Tab
- Generator Monitoring
- Engine Monitoring
- Controller Information Displays, Functions and Reset
- Belt Tensioners
- Operation
- Prestart Checklist
- Manual Starting of the Unit
- Auto (Remote) Starting of the Unit
- Derating for Altitude
- Generator Output Connection Lugs
- Fine Voltage Adjustment
- Voltage Selector Switch
- Voltage Regulation
- Customer Convenience Receptacles
- Main Circuit Breaker
- Exhaust Filter Cleaning Operations
- Transfer Switch
- Auto Exercise Timer
- Shutting Down the Unit
- Emergency Stop Switch
- Idle Switch (MMG25I-45I only)
- Towing the Unit
- Lifting the Unit
- Maintenance
- Emissions Information
- Daily Walk Around Inspection
- General Maintenance
- Basic Maintenance Schedule - Isuzu Engine
- Basic Maintenance Schedule - John Deere Engine
- Isuzu Engine Break-In Requirements
- John Deere Engine Break-In Requirements
- Resetting the Maintenance Alarms
- Checking Generator Drive Plate Torque
- Jack Maintenance
- Trailer Wheel Bearings
- Troubleshooting
- Wiring Diagrams
- AC Wiring - MMG25IF4, MMG45IF4
- AC Wiring - MMG35DF4, MMG55DF4
- AC Wiring - 4 Pos. Voltage Selector Switch Option - MMG25IF4, MMG45IF4
- AC Wiring - 4 Pos. Voltage Selector Switch Option - MMG35DF4, MMG55DF4
- AC Wiring Option - Standard Receptacles
- AC Wiring Option - Engine Heater
- AC Wiring Option - Buck Transformer
- AC Wiring Option - PMG
- DC Wiring
- Trailer Lights Wiring
- Wiring Harness - Electric Brake Option
- DC Wiring Option - 12V Battery Charger
- DC Wiring Option - Low Oil Level
- Options & Accessories
Operation
36949 B MMG25I-35D-45I-55DF4 Operating Manual 33
Set the Schedule
1. Access the Scheduler group by pressing the ► button.
Note: The Scheduler group is made up of the Scheduler Options and Scheduler Setup sections. Each section can
be accessed and exited using the ► and ◄ buttons.
2. Access the Scheduler Options section. Within this section, the scheduler can be enabled, run mode
selected, and load mode selected.
3. Access the Scheduler Setup section. Within this section, each schedule entry can be modified by pressing
the () button to select the item and the ▲ and ▼ buttons to define them.
Note: The controller must be in Auto mode to run at the programmed time. Use a trickle or solar battery charger to
prevent the controller from draining the battery while in Auto mode.
Set the Unit to Auto Mode
1. From any operator or maintenance screen, press and hold the Auto/Manual Mode ( ) button for five seconds,
or until Auto mode is displayed at the top of the screen.
Note: If any of the scheduled time slots are currently active, the controller will begin the starting sequence and start
the unit provided there are no shutdown conditions present.
SHUTTING DOWN THE UNIT
Prior to shutting down the unit, check with personnel using power supplied by the generator and let them know that
the power is going to be turned off. Make sure the power shut down will not create any hazards by accidentally
turning off equipment that needs to be kept on (pumps, compressors, lights, etc.).
1. Remove all loads from the generator by opening all circuit breakers (turn OFF (O)).
2. Let the engine run for approximately five minutes to allow it to cool down.
Table 2: Scheduler Options
Item Values
Enable Yes/No
Run Mode Monthly/Weekly
Load Idle, In Island, On Load, Off Load
Table 3: Scheduler Setup
Item Values
Schedule Entry 1-16
Start Time 00:00-23:59
Duration 00:00-99:59
Day Monday-Sunday
Week (of month) First, Second, Third, Fourth