Spec Sheet

MMG45IF4 | 2.2 L | 45 kVA
MOBILE DIESEL GENERATOR SET
EPA Emissions Certification: Final Tier 4
SPEC SHEET
5 of 6
OPERATING DATA
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please consult a Generac Mobile Products Authorized Service Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, ISO8665, SAE
J1228, SAE J1995, and DIN6271 standards.
POWER RATINGS
Standby: kW/kVA (A) Prime: kW/kVA (A)
1-phase, 120/240 VAC @ 1.0pf* 40/40 (167) 33/33 (138)
3-phase, 120/208 VAC @ 0.8pf 44/55 (153) 38/47 (130)
3-phase, 120/240 VAC @ 0.8pf** 44/55 (132) 38/47 (114)
3-phase, 277/480 VAC @ 0.8pf 44/55 (66) 38/47 (57)
*Alternator limited.
**Power ratings achieved through use of optional 4-position phase switch.
FUEL CONSUMPTION RATES
Load Fuel: gph (Lph)
Standby Prime
50% NA 1.7 (6.4)
75% NA 2.5 (9.4)
100% 3.3 (12.5)