Owner’s Manual for Mobile Light Tower 25
Section 5: Troubleshooting
General Troubleshooting
Some of the more common problems are listed in the
table below. This information is intended to be a check or
verification that simple causes can be located and fixed.
It does not cover all types of problems. Refer to the OEM
engine operator’s manual for additional troubleshooting
information. Procedures that require in-depth knowledge
or skills should be referred to a GMASD.
If problems persist, contact Generac Mobile at 1-800-926-9768 for assistance.
(000139)
WARNING
Risk of burns. Allow engine to cool before 
draining oil or coolant. Failure to do so could 
result in death or serious injury.
General Troubleshooting Guide
Problem Possible Cause Solution
Low oil pressure 
shutdown
Low oil level Verify oil level on dipstick. Add oil, if needed.
Oil leaking from engine Visually inspect the engine for leaks.
Oil pressure switch failure Refer to OEM engine operator’s manual to identify corrective 
action.
High coolant 
temperature shutdown
Low coolant level Add coolant if needed. Allow engine to cool, then check coolant 
level in radiator. Restart engine and check coolant temperature. 
Stop engine immediately if coolant temperature is 210°F (99°C) 
or more.
Blockage in radiator Inspect radiator shroud and ducting for blockage and remove 
any foreign matter.
Leakage in coolant hoses, 
engine block, or water 
pump
Inspect for visible leaks. Verify tension of water pump serpentine 
drive belt.
Remove load on generator and restart engine. Verify coolant 
temperature and shut engine down immediately if it starts to 
overheat. Refer to the OEM engine operator’s manual for 
additional information on engine overheating.
Unit cranks but does not 
start
Fuel level low Check fuel level in tank.
Verify fuel pump operation.
Restricted air filter Inspect air filter for blockage.
Refer to OEM engine operator’s manual for additional 
information.