Manual

2.2 HOURMETER
The Hourmeter tracks hours of operation for scheduled
maintenance:
Therewill be a"CHGOIL"messageevery100 hours.Themessage
will flash one hour before and one hour after each 100 hour
interval, providinga two hourwindow to perform service.
This messagewill actually beginflashing at 99 hours and disable
itself at 101 hours again,providing atwo hourwindow to perform
the service.
Every200 hours the "SVC"icon on the lower left hand corner of
the display will flash. The messagewill flash one hourbefore and
onehourafter each200 hourintervalprovidingatwo hourwindow
to perform service.
Whenthe hour meter is in the FlashAlert mode,the maintenance
message will always alternate with elapsed time in hours and
tenths. The hours wilt flash four times, then alternate with the
maintenancemessagefour times untilthe meter resets itself.
100 hours- CHGOIL-- Oil ChangeInterval(Every100 hrs)
Note:
The hour glassgraphicwill flash on and off when the engine
is running.This signifiesthat the meter is tracking hoursof
operation.
Figure 5 - Hourmeter
I!
oooo.oq
i i
HOURGLASS RESETBUTTON
GRAPHIC (IF EQUIPPED)
2.3 CORDSETSANDCONNECTIONPLUGS
2.3.1 120V4C,20 AMP,DUPLEXRECEPTACLE
This is a 120 Volt outlet protectedagainst overloadby a 20 Amp
push-to-resetcircuit breaker (Figure6). Useeach socketto power
120 Volt AC, single phase,60 Hzelectrical loads requiringup to a
combined 2400 watts (2.4 kW) or 20 Amps of current. Use only
high quality, welt-insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
Keep extensioncords as short as possible, preferably less than
15 feet long, to preventvoltage drop and possibleoverheatingof
wires.
Figure 6 - 120 Volt AC, 20 Amp, Duplex Receptacle
D
2.3.2 120/240 V4C,30AMPRECEPTACLE
Use a NEMA L14-30 plug with this receptacle (rotate to lock/
unlock). Connecta suitable4-wire groundedcord set to the plug
andto the desiredtoad.The cord set should be ratedfor 250 Volts
AC at 30 Amps (or greater)(Figure7).
Figure 7 - 120/240 VAC, 30 Amp Receptacle
120V/240V
30A
Use this receptacleto operate 120 Volt AC, 60 Hz, single phase
loads requiringup to 3600 watts (3.6 kW) of power at 30 Amps or
240 Volt AC,60 Hz, singlephase loads requiringup to 7200 watts
(7.2 kW) of power at 30 Amps. The outlet is protectedby two 30
Amp push-to-resetcircuit breakers.
2.4 HOWTOUSETHEGENERATOR
If there are any problems operatingthe generator,pleasecall the
generatorhetplineat 1-888-436-3722.
Using a generator indoors CAN KILL YOU iN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.