Manual

NOTE: NOTE:
if enginefires, but doesnot continueto run,move chokelever
to FULLCHOKEand repeatstartinginstructions.
IMPORTANT:Do not overloadthe generator.Also, do not overload
individual panel receptacles.These outlets are protected against
overload with push-to-reset-type circuit breakers. If amperage
rating of any circuit breakeris exceeded,that breaker opens and
electricaloutputto that receptacleis lost. Read"Don't Overloadthe
Generator"carefully.
2.10STOPPINGTHEENGINE
Shutoff all loads,then unplugthe electricalloadsfrom generator
panelreceptacles.Neverstart or stop the enginewith electrical
devices pluggedin andturned on.
Let engine run at no-load for several minutes to stabilize the
internaltemperaturesof engineandgenerator.
Move Run/Stopswitch to OFFposition.
Closefuel valve.
2.11LOWOiLLEVELSHUTDOWNSYSTEM
The engineis equippedwith a low oil levelsensorthat shuts down
the engineautomaticallywhenthe oil leveldrops below a specified
level. If the engine shuts down by itself and the fuel tank has
enoughgasoline,check engineoil level.
2.11.1 SENSINGLOWOILLEVEL
If the system senses a low oil level during operation,the engine
shuts down. The enginewill not run until the oil has beenrefilled
to the properlevel.
2.12CHARGINGTHEBATTERY(ELECTRICSTART
UNITSONLY)
Storage batteries give off explosive hydrogen
gas while recharging. An explosive mixture will
remain around the battery for a long time after
it has been charged. The slightest spark can
ignite the hydrogen and cause an explosion.
Such an explosion can shatter the battery and
cause blindness or other serious injury.
,_Do not permit smoking, open flame, sparks
or any other source of heat around a battery.
Wear protective goggles, rubber apron and
rubber gloves when working around a battery.
Battery electrolyte fluid is an extremely
corrosive sulfuric acid solution that can cause
severe burns, if spill occurs flush area with
clear water immediately.
Thebattery shipped withthe generatorhasbeen fully charged.
A battery may lose some of its charge when not in use for
prolongedperiodsof time. If the battery is unable to crank the
engine, plugin the 12V chargerincludedin the accessory box
(see section"Chargingthe Battery"). RUNNINGTHEGENERATOR
DOESNOTCHARGETHEBATTERY.
Usebattery chargerplugto keepthe battery chargedandreadyfor
use. Batterycharging should be done in a dry location.
1. Plugcharger into "Battery ChargerInput" jack, locatedon the
control panel.Plugwall receptacleend of the battery charger
into a 120 Volt AC wall outlet (Figure13).
2. Unplugbattery chargerfrom wall outlet andcontrol paneljack
when generatoris goingto be in use.
NOTE:
Do not use the battery chargerfor more than 48 hours at one
charge.
Figure 13 - Battery Charger Jack
BATTERY
CHARGER
INPUT
3.1 MAINTENANCESCHEDULE
Follow the calendar intervals. More frequent service is required
when operatingin adverseconditions noted below.
CheckOil Level
ChangeOil
CheckValveClearance
ServiceAir Filter
ReplaceSpark Plug
At Each Use
*Every 100 hours or EverySeason
***Every Season
** Every200 hours or EverySeason
EverySeason
:i: Changeoil after first 30 hours of operationthen every season.
* Changeoil and oil filter every monthwhen operatingunder heavyload or in high
temperatures.
** Cleanmore often under dirty or dusty operatingconditions. Replace air filter
parts if they cannot be adequatelycleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of
operationand every 100 hours thereafter.
1o