TurnengineRUN/STOPswitch to ON position(Figure11).
Slideenginechoketo the LEFTto FULLCHOKEposition (Figure
12).
Tostart engine,firmly grasp the recoil handleand pull slowly
until increasedresistanceis felt. Puttrapidly up and away.
Whenenginestarts, move choke knob to 1/2-CHOKEposition
until engineruns smoothly and then fully into RUN position. If
engine falters, move choke back out to 1/2-CHOKEposition
until engineruns smoothly andthen to RUNposition.
NOTE:
if enginefires, but does notcontinueto run,move chokelever
to FULLCHOKEand repeatstartinginstructions.
Figure 10 - Fuel Shut-off Valve
FUEL 3HUTOFF
Figure 11 - Engine ON/OFF Switch
ENGINE ON/OFF SWITCH
(PULL START ENGINES ONLY)
\
=11
Figure 12 - Choke Position
CHOKELEVER
LEFT= CHOKE--
RIGHT = RUN
IMPORTANT:Do not overloadthe generator.Also, do not overload
individual panel receptacles.These outlets are protected against
overload with push-to-reset-type circuit breakers. If amperage
rating of any circuit breakeris exceeded,that breakeropens and
electricaloutputto that receptacleis lost. Read"Don't Overloadthe
Generator"carefully.
2.g STARTINGELECTRICSTARTENGINES
z_Never start or stop engine with electrical
devices plugged into the receptacles AND
devices turned on.
Unplug all electrical loads from the unit's receptaclesbefore
starting the engine.
Make surethe unit is in a level position (not to exceed15° in
any direction).
Openthefuel shut-off valve (Figures10).
Move engine CHOKEknob outward to FULLCHOKEposition
(Figure12).
Tostart engine,pressandhold the Start/Run/Stopswitch in the
"Start" position (Figure10). The enginewill crankand attempt
to start. When the enginestarts, releasethe switch to the run
position.
When the engine starts, move choke knob to "1/2 Choke"
position until the engineruns smoothly and then fully into the
"Run" position. If enginefalters, move chokeknob back out to
"1/2 Choke" position until the engine runs smoothly and then
to "Run" position.
This generatoris also equippedwith a manual recoil starter
which may be used if the battery is discharged.
NOTE:
The switch must be in the RUN position. Use one of the
generator's receptacle outlets along with the includedbattery
chargerto chargethe battery whilethe generator is running.
Tostart manually,firmly graspthe recoil handleand pull slowly
until increasedresistanceis felt. Pull rapidly up and away to
start engine.Thenfollow the same chokesequence.