Brochure

1-888-GENERAC
Specifications
Enhance your Generac standby generators performance with accessories from the leader in standby power.
Products are available to maximize convenience and simplify maintenance for years of reliable standby power.
Automatic Standby Generators - Air-Cooled
Pre-packaged models N/A 5837 6237 6437 / 6438* 6240 / 6241* 6242 6243* 6244*
Non pre-packaged models
5818 N/A 6245 6439 6247 6248 6249 6250
Rated Power (LPG/NG) 6 kW* 7/6 kW 8/7 kW 11/10 kW 14/13 kW 17/16 kW 17/16 kW 20/18
Voltage (Single Phase) 120V
(
240V capable
w/kit 6016
)
240V 240V 240V 240V 240V 240V 240V
Amps @ 240V LPG 50
(25 @ 240V)
29.2 33.3 45.8 58.3 70.8 70.8 83.3
Amps @ 240V NG N/A 25 29.2 41.7 58.3 66.6 66.6 75
Engine/Alternator RPM 2600 3600 / 3600 3600 / 3600 3600 / 3600 3600 / 3600 3600 / 3600 3600 / 3600 3600 / 3600
Engine OHVI / 530cc 432cc Vertical OHVI / 410cc OHVI / 530cc OHVI / 992cc OHVI / 992cc OHVI / 992cc OHVI / 999cc
Fuel Consumption @ full load
LPG cu. ft/hr (gal. hr)
56.4 (155) 46 (1.26) 51.6 (1.42) 70 (1.92) 111.6 (3.07) 130 (3.57) 130 (3.57) 140 (3.85)
Fuel Consumption @ Full Load
NG cu. ft/hr (gal. hr)
N/A 148 121 145 279 312 312 308
Quiet-Test Mode No No No No No Yes Yes Yes
db(A) at Exercise 52 67 62 63 66 60 60 60
db(A) at Normal Operating Load 52 67 62 63 66 66 66 66
Automatic Transfer Switch OHVI / 530cc 50 Amp 50 Amp 50 / 200 Amp 100 / 200 Amp 100 Amp 200 Amp 200 Amp
Circuits Included OHVI / 530cc 8 10 12 14 16 NA NA
Enclosure Steel Composite Steel Steel Steel Steel Aluminum Aluminum
Enclosure Color Bisque Bisque Bisque Bisque Bisque Bisque Gray Gray
Warranty 3 Year Limited 2 Year Limited 5 Year Limited 5 Year Limited 5 Year Limited 5 Year Limited 5 Year Limited 5 Year Limited
Dimensions (L" x W" x H") 48x25x29 24 x 30 x 33 48 x 25 x 29 48 x 25 x 29 48 x 25 x 29 48 x 25 x 29 48 x 25 x 29 48 x 25 x 29
Generator Weight (lbs.) 387 243 360 407 435 471 437 451
CARB Compliant N0 Yes Yes Yes Yes Yes Yes Yes
Transfer Switch Weight (lbs.) N/A 25 53.5 57 / 39 64 / 39 68 39 39
EcoGen
Guardian Series
20 21
CorePower
* Rating denitions - Standby: Applicable for supplying emergency power for the duration of the charging period. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage
and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease