Product Manual
Table Of Contents
- GP Series Portable Generator Owner’s Manual
- Table of Contents
- Section 1 Introduction and Safety
- Section 2 General Information and Setup
- Section 3 Operation
- Operation and Use Questions
- Before Starting Engine
- Prepare Generator for Use
- Grounding the Generator When Used as a Portable
- Know Generator Limits
- Transporting/Tipping of the Unit
- Starting Pull Start Engines
- Starting Electric Start Engines
- Low Oil Level Shutdown System
- Charging the Battery (electric start units only)
- Section 4 Maintenance and Troubleshooting
- Part No. 10000029705
- Generador portátil serie GP Manual del usuario
- Índice de contenidos
- Sección 1 Introducción y seguridad
- Sección 2 Información general y configuración
- Sección 3 Funcionamiento
- Preguntas sobre uso y funcionamiento
- Antes de arrancar el motor
- Preparación del generador para su uso
- Conexión a tierra del generador cuando se utiliza como aparato portátil
- Conozca los límites del generador
- Transporte o inclinación de la unidad
- Arranque de motores con el tirador de arranque
- Arranque de motores con arranque eléctrico
- Sistema de cierre por nivel bajo de aceite
- Cargar la batería (sólo arranque eléctrico)
- Sección 4 Mantenimiento y solución de problemas
- Pieza Nº 10000029705
- Générateur portatif GP Manuel du propriétaire
- Table des matières
- Section 1 Introduction et règles de sécurité
- Section 2 Informations générales et installation
- Section 3 Fonctionnement
- Questions relatives au fonctionnement
- Avant de démarrer le moteur
- Préparation du générateur à l’utilisation
- Mise à la terre du générateur utilisé comme appareil portatif
- Connaître les limites de son générateur
- Transport/Inclinaison de l’appareil
- Démarrage des moteurs à démarrage manuel
- Démarrage des moteurs à démarrage électrique
- Système d’arrêt en cas de faible niveau d’huile
- Chargement de la batterie (unités à démarrage électrique uniquement)
- Section 4 Maintenance et dépannage
- Numéro de pièce 10000029705
Owner’s Manual for Portable Generator 7
Hour Meter
The Hour Meter tracks hours of operation for
scheduled maintenance. See Figure 2-4.
• The CHG OIL display will illuminate every
100 hours. The message will flash one hour
before and one hour after each 100 hour
interval, providing a two hour window to
perform service.
• The SVC display will illuminate every 100
hours. The message will flash one hour
before and one hour after each 200 hour
interval providing a two hour window to per-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
• 100 hours - CHG OIL — Oil Change Inter-
val (Every 100 hrs)
• 200 hours - SVC — Service Air Filter
(Every 200 hrs)
NOTE: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
Figure 2-4. Hour Meter
Connection Plugs
120 VAC, 20 Amp, GFCI Duplex
Receptacle
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See Fig-
ure 2-5. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
Figure 2-5. 120 VAC, 20 Amp, GFCI Duplex
Receptacle NEMA 5-20R
120/240 VAC, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 4-
wire grounded cord set to plug and desired
load. The cord set should be rated 250 Volts
AC at 30 Amps (or greater). See Figure 2-6.
Use this receptacle to operate 120 Volt AC, 60
Hz, single phase loads requiring up to 3600
watts (3.6 kW) of power at 30 Amps or 240
Volt AC, 60 Hz, single phase loads requiring
up to 7200 watts (7.2 kW) of power at 30
Amps. The outlet is protected by one 30 Amp
2-pole circuit breaker.
8.0kW Engine Specifications
Displacement 420cc
Spark Plug Part No. 0J00620106
Spark Plug Gap 0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity 28.4 L (7.5 gal)
Oil Type
See Chart in
Add Engine Oil
Oil Capacity 1.0 L (1.06 qt.)
Run Time at 50% Load 11 Hours
* Go to Generac.com or contact an IASD for replacement parts.