Product Manual
Table Of Contents
- GP Series Portable Generator Owner’s Manual
- Table of Contents
- Section 1 Introduction and Safety
- Section 2 General Information and Setup
- Section 3 Operation
- Operation and Use Questions
- Before Starting Engine
- Prepare Generator for Use
- Grounding the Generator When Used as a Portable
- Know Generator Limits
- Transporting/Tipping of the Unit
- Starting Pull Start Engines
- Starting Electric Start Engines
- Low Oil Level Shutdown System
- Charging the Battery (electric start units only)
- Section 4 Maintenance and Troubleshooting
- Part No. 10000029705
- Generador portátil serie GP Manual del usuario
- Índice de contenidos
- Sección 1 Introducción y seguridad
- Sección 2 Información general y configuración
- Sección 3 Funcionamiento
- Preguntas sobre uso y funcionamiento
- Antes de arrancar el motor
- Preparación del generador para su uso
- Conexión a tierra del generador cuando se utiliza como aparato portátil
- Conozca los límites del generador
- Transporte o inclinación de la unidad
- Arranque de motores con el tirador de arranque
- Arranque de motores con arranque eléctrico
- Sistema de cierre por nivel bajo de aceite
- Cargar la batería (sólo arranque eléctrico)
- Sección 4 Mantenimiento y solución de problemas
- Pieza Nº 10000029705
- Générateur portatif GP Manuel du propriétaire
- Table des matières
- Section 1 Introduction et règles de sécurité
- Section 2 Informations générales et installation
- Section 3 Fonctionnement
- Questions relatives au fonctionnement
- Avant de démarrer le moteur
- Préparation du générateur à l’utilisation
- Mise à la terre du générateur utilisé comme appareil portatif
- Connaître les limites de son générateur
- Transport/Inclinaison de l’appareil
- Démarrage des moteurs à démarrage manuel
- Démarrage des moteurs à démarrage électrique
- Système d’arrêt en cas de faible niveau d’huile
- Chargement de la batterie (unités à démarrage électrique uniquement)
- Section 4 Maintenance et dépannage
- Numéro de pièce 10000029705
Owner’s Manual for Portable Generator 11
Figure 2-12. Safe Operating Range
7. Install oil fill cap/dipstick and hand-tighten.
Fuel
Fuel requirements are as follows:
• Clean, fresh, unleaded gasoline.
• Minimum rating of 87 octane/87 AKI (91
RON).
• Up to 10% ethanol (gasohol) is acceptable
(where available; non-ethanol-premium fuel
is recommended).
• DO NOT use E85.
• DO NOT use a gas oil mix.
• DO NOT modify engine to run on alternate
fuels. Stabilize fuel prior to storage.
1. Verify unit is OFF and cooled for a mini-
mum of two minutes prior to fueling.
2. Place unit on level ground in a well venti-
lated area.
3. Clean area around fuel cap and remove
cap slowly.
4. Slowly add recommended fuel (A). Do not
overfill (B). See Figure 2-13.
5. Install fuel cap.
Figure 2-13. Add Recommended Fuel
NOTE: Allow spilled fuel to evaporate before
starting unit.
IMPORTANT NOTE: It is important to pre-
vent gum deposits from forming in fuel
system parts such as the carburetor, fuel
hose or tank during storage. Alcohol-
blended fuels (called gasohol, ethanol or
methanol) can attract moisture, which
leads to separation and formation of acids
during storage. Acidic gas can damage the
fuel system of an engine while in storage.
To avoid engine problems, the fuel system
should be emptied before storage of 30
days or longer. See the Storage section.
Never use engine or carburetor cleaner
products in the fuel tank as permanent
damage may occur.
000116
(000105)
DANGER
Explosion and Fire. Fuel and vapors are
extremely flammable and explosive. Add fuel
in a well ventilated area. Keep fire and spark
away. Failure to do so will result in death
or serious injury.
(000106b)
Fluid Injection. This machine produces
high-pressure fluid streams that can pierce
skin. Fluid injection could result in death or
serious injury.
WARNING
000400
A
B