Checking Engine Oil Level
IMPORTANT NOTE: Verify oil level daily when power
outages necessitate running generator for extended
periods. Generator will shut down if oil level is low. 
Proceed as follows to check engine oil level:
1. Set utility MLCB to OFF (OPEN).
2. Set  generator  MLCB  (generator  disconnect)  to
OFF (OPEN).
3. Allow  generator  to  run  for  a  cool-down  period  of
approximately  one  minute,  if  generator  was  run-
ning during an outage.
4. Press  OFF  button  to  turn  generator  off.  Wait  five
minutes.
5. See  Figure  2-1,  Figure  2-2,  or  Figure  2-3.
Remove  oil  dipstick  and  wipe  it  dry  with  a  clean
cloth.
6. Completely  insert  oil  dipstick into oil  dipstick  tube
and remove.
7. Observe oil level. Oil level should be at FULL mark
on oil dipstick.
8. If  necessary,  remove  oil  fill  cap  and  add  recom-
mended  oil  to  engine  (with  oil  dipstick  removed)
until oil level reaches FULL mark. Insert oil dipstick
and install fill cap. See Engine Oil Requirements.
To restart generator:
1. Press AUTO button on control panel.
2. Allow generator to start and warm up for a few min-
utes.
3. Set generator MLCB (generator disconnect) to ON
(CLOSED).
The system is now operating in AUTO. The utility MLCB
can be turned ON (CLOSED).
Engine Oil Requirements
Engine oil should be serviced in accordance with the rec-
ommendations  of  this  manual  to  maintain  product  war-
ranty. Generac maintenance kits consisting of engine oil,
oil filter, air filter, spark plug(s), a shop towel, and a funnel
are available through an IASD.
All  Generac  oil  kits meet  minimum American Petroleum
Institute (API) Service Class SJ, SL, or better. Do not use
special additives.
Synthetic  SAE  5W-30  for  all  temperature  ranges.  See
Engine.
Changing the Oil and Oil Filter
Proceed as follows to change oil and oil filter:
1. Lift lid and press MANUAL button on control panel
to  start  engine,  and  run  unit  until  it  is  thoroughly
warmed up. Press OFF button on control panel to
shut down engine.
2. See  Figure  4-1,  Figure  4-2,  or  Figure  4-3.
Remove front panel when unit has cooled. Pull oil
drain  hose  (A)  free  of  retaining  clip.  Remove  cap
from oil drain hose and place free end into a suit-
able container. Drain oil.
Figure 4-1. Oil Filter and Drain Location (10 kW)
(000139)
WARNING
Risk of burns. Allow engine to cool before 
draining oil or coolant. Failure to do so could 
result in death or serious injury.
(000210)
WARNING
Skin irritation. Avoid prolonged or repeated contact with 
used motor oil. Used motor oil has been shown to cause 
skin cancer in laboratory animals. Thoroughly wash 
exposed areas with soap and water. 
(000135)
Engine damage. Verify proper type and quantity of 
engine oil prior to starting engine. Failure to do so 
could result in engine damage.
CAUTION
(000135)
Engine damage. Verify proper type and quantity of 
engine oil prior to starting engine. Failure to do so 
could result in engine damage.
CAUTION
001831