Replacement Part List
5 of 6
®
Limited Circuits Switch Features
 16 space, 24 circuit. Breakers not included.
 Electrically operated, mechanically-held contacts for fast, positive connections.
 Rated for all classes of load, 100% equipment rated, both inductive and 
resistive.
 2-pole, 250 VAC contactors.
 30 millisecond transfer time.
 Dual coil design.
 Rated for both copper and aluminum conductors.
 Main contacts are silver plated or silver alloy to resist welding and sticking.
 NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor 
mounting flexibility.
 Multi listed for use with 1 in standard, tandem, GFCI, and AFCI breakers from 
Siemens, Murray, Eaton, and Square D for the most flexible and cost effective 
install.
*Function of Evolution controller
 Exercise can be set to weekly or monthly
Model
G007172-0
(10 kW)
G007174-0 
(13 kW)
G007177-0 
(16 kW)
No. of poles  2
Current rating (amps) 100
Voltage rating (VAC) 120 / 240, 1Ø
Utility voltage monitor (fixed)*
-Pick-up
-Dropout
80%
65%
Return to utility* Approx. 15 sec
Exercises bi-weekly for 
5 minutes*
Standard
ETL or UL Listed Standard
Total circuits available 24
Tandem breaker capabilities 8 tandems
Circuit breaker protected
 Available RMS Symmetrical
 Fault Current @ 250 Volts
10,000
H2
DEPTH
H1
W2
W1
10/13/16 kW
Dimensions
Height Width
Depth
H1 H2 W1 W2
in 26.75 30.1 10.5 13.5 6.91
cm 67.94 76.43 26.67 34.18 17.54
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
2/0 - #14 2/0 - #14 2/0 - #14
Dimensions
Service Rated Smart Switch Features
Includes Smart A/C Management (SACM) module standard.
 Intelligently manages up to four air conditioner loads with no additional 
hardware.
 Up to eight large (240 VAC) loads can be managed with Smart Management 
Modules (SMMs).
Electrically operated, mechanically-held contacts for fast, clean connections.
 Rated for all classes of load, 100% equipment rated, both inductive and 
resistive.
2-pole, 250 VAC contactors.
Service equipment rated, dual coil design.
Rated for both aluminum and copper conductors.
Main contacts are silver plated or silver alloy to resist welding and sticking.
 NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor 
mounting flexibility.
200 Amps 120/240, 1ø
Open Transition Service Rated
Height Width
Depth
H1 H2 W1 W2
in 26.75 30.1 10.5 13.5 6.3
cm 67.94 76.45 26.67 34.3 16.01
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
400 MCM - #4 350 MCM - #6 2/0 - #14
*Function of Evolution Controller
 Exercise can be set to weekly or monthly
Model
G007175-0 
(13 kw)
G007178-0 
(16 kW)
No. of poles  2
Current rating (amps) 200
Voltage rating (VAC) 120/240, 1Ø
Utility voltage monitor (fixed)*
-Pick-up
-Dropout
80%
65%
Return to utility* 15 sec
Exercises bi-weekly for 5 minutes* Standard
ETL or UL Listed Standard
Enclosure type NEMA/UL 3R
Circuit breaker protected 22,000
Lug range 250 MCM - #6
H2
DEPTH
H1
W2
W1
Switch Options10/13/16 kW






