Spec Sheet
2 of 5
®
Engine
Generac (OHV) design Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings
help the engine run cooler, reducing oil consumption and resulting in longer engine life.
Cast iron cylinder walls Rigid construction and added durability provide long engine life.
Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
High temperature shutdown Prevents damage due to overheating.
Generator
Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
Displaced phase excitation Maximizes motor starting capability.
Automatic voltage regulation Regulating output voltage to ±5% prevents damaging voltage spikes.
UL 2200 listed For your safety.
Transfer Switch
Fully automatic Transfers vital electrical loads to the energized source of power.
Remote mounting Mounts near existing distribution panel for simple, low cost installation.
Flush mountable Can be installed between studs like a standard electrical panel.
UL 1008 listed For your safety.
Digital Controls
Multiple LED annunciation Provides specific system information without having to open the generator enclosure.
AUTO/OFF/MANUAL buttons Select the operating mode.
Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
Utility interrupt delay Prevents nuisance start-ups of the engine, setpoint approximately 5 seconds.
Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 6 seconds.
Engine cool-down Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Cold Smart Start If the ambient temperature is cold, allows the engine to warm up before load is applied.
Seven day exerciser Operates engine to prevent oil seal drying and damage between power outages.
Smart battery charger Maintains battery charge level to ensure starting.
Main line circuit breaker Protects generator from overload.
Multiple protection features Prevents additional damage from occurring within the generator if a fault condition arises.
Unit
UL weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature. Three panels are
removable for easy service and maintenance access.
Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
Installation System
14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.
7.5 kW