Product Manual A
General Information
30 MTP4000-6000DZV/DZD Operating Manual 31609 A
Note: This screen can not be exited until the checksum calculation is complete. Checksum calculation takes
approximately 10 seconds and is complete when the checksum value changes from “Calculating”… to a hexadecimal
value such as 0x704E – OK.
AUTOSTART MENU
This submenu allows the user to configure automatic start/stop operation. Refer
to “Automatic Start/Stop Operation” on page 19 for more information.
Mode
This menu selects the basic automatic start/stop operation mode. Button 4 cycles
between Single Switch, Dual Switch, Transducer or Xducer & Sw.
Function
This menu selects the automatic start/stop function. Button 4 cycles between
Empty, Fill, Maintain Out and Maintain In.
Throttling Menu
The throttling menu allows the user to configure throttle control. It also allows
programming the automatic start/stop throttle profiles as shown in Figure 12 on page
19.
Idle RPM
Selects the RPM the control system will request for idle speed. Idle can be set to
compensate for parasitic loads such as hydraulic pumps or compressors. Idle RPM
is the low speed setting of the optional two state or three state throttle switches.
Note: The minimum engine speed is set by the ECU. Requesting a lower speed causes the engine to run at the
ECU minimum speed. RPM limits are programmed into the panel to limit the requested speed. Contact Generac
Mobile Products, LLC for information on changing the panel minimum requested RPM and maximum requested RPM.
Intermediate RPM
Selects the RPM the control system will request for intermediate speed. The intermediate speed can be used to
prime pump or charge lines during automatic start/stop operation. Intermediate RPM is the middle setting of optional
three state throttle switches.
Note: Setting the Intermediate RPM to the same speed as Idle RPM and Ramp to Run to zero seconds is effectively
two speed automatic operation.
Run RPM
Selects the RPM the control system will request for run speed. The run speed is the normal operating speed during
automatic start/stop operation. Run RPM is the high speed setting of the optional two state or three state throttle
switches.