Product Manual A
General Information
31609 A MTP4000-6000DZV/DZD Operating Manual 17
switch inputs and a transducer input support a number of control scenarios. Single switch mode allows reliable
operation with a single switch. Dual switch operation allows greater hysteresis when needed.
The transducer input supports simple start/stop operation by level or pressure and maintenance modes with speed
modification.
• Programmable high and low set points control start/stop operation.
• Level maintenance modes monitor the operating point and adjust the engine speed to match the targeted
set point with configurable aggressiveness.
• Dual switch inputs can be combined with the transducer input for redundant safety to protect against
transducer sensor clog or failure.
Throttle Control
The standard ramp throttle uses a momentary rocker switch to adjust the integral throttle control. All throttle commands
are sent directly to the engine using CANbus throttle control.
Service Timers
The CP750™ display provides 16 service timers to alert the operator of needed maintenance. The time interval for
each timer can be adjusted in 10 hour increments. A pop-up message is displayed after the display self test if a timer
has expired, alerting the user that service is required. The message is displayed on each power up until the elapsed
timer is disabled or reset.
CANplus Messenger Telemetry Option
The optional CANplus Messenger system provides a variety of features to protect and support the equipment
investment. Remote monitoring can alert maintenance requirements, operational problems, improper operation and
location with geo-fence alert. The web-browser interface allows monitoring an entire fleet of equipment in a central
location. Contact Generac Mobile Products, LLC for more information.
Button Lock
The control panel’s five buttons can be locked so the operator does not accidentally change settings or access
another display mode. Button Lock is enabled by pressing and holding buttons 1 and 5 simultaneously for one second.
Repeating this operation restores normal button operation.