Product Manual
5
can cause nausea, fainting or death. Make sure engine exhaust cannot seep into closed rooms or
ventilation equipment.
• DO NOT operate the unit on a combustible surface.
• DO NOT fill fuel tank near an open flame, while smoking, or while engine is running. DO NOT fill tank
in an enclosed area with poor ventilation.
• DO NOT operate with the fuel tank cap loose or missing.
• DO NOT touch or lean against hot exhaust pipes or engine cylinders.
• DO NOT clean air filter with gasoline or other types of low flash point solvents.
• DO NOT remove engine coolant cap while engine is hot.
• DO NOT operate the unit without a functional exhaust system. Prolonged exposure to sound levels
in excess of 85 dB(A) can cause permanent hearing loss. Wear hearing protection when working
around a running engine.
• Keep area around exhaust pipes and air ducts free of debris to reduce the chance of an accidental fire.
• Batteries contain sulfuric acid which can cause severe injury or death. Sulfuric acid can cause eye
damage, burn flesh or eat holes in clothing. Protective eye wear and clothing are necessary when
working on or around the battery. Always disconnect the negative (-) battery cable from the
corresponding terminal before performing any service on the engine or other components.
• Shut the engine down if any of the following conditions exist during operation:
1. Noticeable change in engine speed.
2. Loss of electrical output.
3. Equipment connected to the generator overheats.
4. Sparking occurs.
5. Engine misfires or there is excessive engine/generator vibration.
6. Protective covers are loose or missing.
7. If the ambient air temperature is above 120°F (49°C).
SERVICE SAFETY
This unit uses high voltage circuits capable of causing serious injury or death. Only a qualified electrician
should troubleshoot or repair electrical problems occurring in this equipment.
• Before servicing, make sure the Control Power switch is turned to OFF, circuit breakers are open
(OFF (O) position) and the negative terminal on the battery is disconnected. NEVER perform even
routine service (oil/filter changes, cleaning, etc.) unless all electrical components are shut down.
• NEVER allow water to accumulate around the base of the unit. If water is present, DO NOT service.
• NEVER service electrical components if clothing or skin is wet. If the unit is stored outside, check the
engine and generator for any moisture and dry the unit before use.
• NEVER wash the unit with a power washer or high pressure hose.
• Open the main circuit breaker before disconnecting battery cables.
• Keep all body parts, clothing, and other loose items away from moving parts on the unit.
• Make sure slings, chains, hooks, ramps, jacks, and other types of lifting devices are attached securely
and have enough weight-bearing capacity to lift or hold the unit safely. Always remain aware of the
position of other people around when lifting the unit.
• NEVER start the unit under load. The circuit breakers must be in the OFF (O) position when starting
the unit.