Brochure
Model MMG 175
MMG 175
153 / 191
230 / 530
138 / 172
207 / 477
125 / 125
521
120 / 120
500
60
1 (1Ø), 0.8 (3Ø)
Marathon/Brushless/H
68
Yes
144 x 50 x 77
6604 (2996)
9032 (4097)
210 x 86 x 93
8000 (3629)
10428 (4730)
Interim Tier 4
John Deere
PE6068HFG94
Turbo
217 (162)
415 (6.8)
6
1800
10.9 (41.3)
1-12V/1000 CCA
342 (1295)
29
700
+/-1%
2
NA
3
2 - 6000 (2722)
16
Surge
3” Ring
MMG 185
177 / 221
266 / 613
162 / 202
243 / 561
151 / 151
629
137 / 137
571
60
1 (1Ø), 0.8 (3Ø)
Marathon/Brushless/H
68
Pending
132 x 50 x 77
6510 (2953)
9100 (4128)
210 x 86 x 93
8450 (3833)
11040 (5008)
Tier 3 Flex
John Deere
PE6068HF485
Turbo
258 (193)
415 (6.8)
6
1800
12.3 (46.6)
1-12V/1000 CCA
342 (1295)
25
700
+/-1%
2
NA
3
2 - 7000 (3175)
16
Surge
3” Ring
MMG 150
127 / 159
191 / 441
116 / 145
174 / 402
114 / 114
475
106 / 106
442
60
1 (1Ø), 0.8 (3Ø)
Marathon/Brushless/H
68
Yes
132 x 50 x 77
5944 (2696)
8500 (3856)
210 x 86 x 93
7340 (3329)
9896 (4489)
Tier 3 Flex
John Deere
PE4045HF285
Turbo
179 (134)
275 (4.5)
4
1800
8.5 (32.3)
1-12V/1000 CCA
342 (1295)
36
600
+/-1%
2
NA
3
2 - 6000 (2722)
16
Surge
3” Ring
MMG 130
107 / 134
161 / 372
98 / 122
149 / 339
96 / 96
400
90 / 90
375
60
1 (1Ø), 0.8 (3Ø)
Marathon/Brushless/H
68
Pending
144 x 50 x 77
5444 (2469)
7929 (3596)
210 x 86 x 93
6840 (3102)
9325 (4230)
Interim Tier 4
John Deere
PE4045HFG93
Turbo
152 (113)
275 (4.5)
4
1800
7.4 (28.0)
1-12V/1000CCA
342 (1295)
44
450
+/-1%
2
NA
3
2 - 6000 (2722)
16
Surge
3" Ring
Limited availability of Tier 3 Flex engines – Call for Details
MMG 120
102 / 127
153 / 353
93 / 116
147 / 339
91 / 91
379
85 / 85
354
60
1 (1Ø), 0.8 (3Ø)
Marathon/Brushless/H
68
Yes
132 x 50 x 77
5429 (2463)
7914 (3590)
210 x 86 x 93
6825 (3096)
9310 (4223)
Tier 3 Flex
John Deere
PE4045HF285
Turbo
144 (107)
275 (4.5)
4
1800
7.4 (28)
1-12V/1000 CCA
342 (1295)
44
450
+/-1%
2
NA
3
2 - 6000 (2722)
16
Surge
3” Ring
3 Position Switch (lockable)3 Position Switch (lockable)3 Position Switch (lockable)
Specications are subject to
change without notice.
120, 139, 208, 220, 240, 277
208, 220, 440, 480
120, 139, 208, 220, 240, 277
208, 220, 440, 480
120, 139, 208, 220, 240, 277
208, 220, 440, 480
Mobile Generator
Specications
Model
Output
3 Phase - Standby (kW/kVA)
Amps (480/208 V)
3 Phase - Prime (kW/kVA)
Amps (480/208 V)
1 Phase - Standby (kW/kVA)
Amps (240V)
1 Phase - Prime (kW/kVA)
Amps
AC Voltage 1-phase
AC Voltage 3-phase
Frequency Hz
Power Factor
Generator (Brand/Type/Insulation)
Sound (dB(A) 23 Feet @ prime)
CSA Listed
Size and Weight
Skid Mounted ( l x w x h ) in
Dry Weight lb (kg)
Operating Weight lb (kg)
Trailer Mounted ( l x w x h ) (in)
Dry Weight lb (kg)
Operating Weight lb (kg)
Engine
Brand
Model #
Aspiration
HP (prime @ 1800rpm) (kW)
Displacement in
3
(L)
Cylinders
Speed (rpm)
Fuel Consumed prime gph (Lph)
Battery (12 volt)
Capacities
Fuel Tank gal (L)
Approximate Run Time hrs
AC Distribution
Main Breaker
Voltage Selection
Voltage Regulation
120V - 20 amp GFCI Duplex
240V - 30 amp Twist Lock
240V - 50 amp Twist Lock
Trailer
# of Axles & Capacity lbs (kg)
Tire Size (in)
Brakes
Hitch – Standard
Specications or designs are
subject to change without notice.
7