Product Brochure

0L0124 Printed in USA Rev. A 10/2014
©2014 Generac Power Systems, Inc. All rights reserved.
Specications are subject to change without notice.
GENERATOR
Model 6103
(15 kW)
Rated Maximum Continuous Power Capacity (NG/LP) 15,000 W / 15,000 W
Rated Voltage 240 V
Rated Maximum Continuous Load Current – 240 Volts 62.5 / 62.5
Main Line Circuit Breaker 65 Amps
Phase 1
Number of Sliprings 3
Rated AC Frequency 60Hz
Power Factor 1
Battery Requirement (not included)
Group 26R 12 Volts
and 525 Cold-cranking
Amperes Minimum
Unit Weight (Pounds / Kilos) 536 / 243.1
Dimensions (L x W x H) Inches
[mm]
48 x 25 x 29
[1218 x 638 x 732]
Sound output in dB(A) at 23 ft.
with generator operating at normal load
63
ENGINE
Type of Engine Generac OHVI V-twin
Number of Cylinders 2
Displacement 999cc
Cylinder Block
Aluminum
w/Cast Iron Sleeves
Valve Arrangement Overhead Valve
Ignition System
Solid-state
with Magneto
Governor System Electronic
Compression Ratio 9.5:1
Starter 12 Vdc
Engine Oil Capacity Including Filter
(quarts / liters) 1.9 Qt / 1.8 L
Oil Reservoir Capacity
(quarts / liters) 3.75 Qt / 3.55 L
Engine Operating RPM 2700-3600
Fuel Consumption
Natural Gas - ft
3
/hr (m
3
hr) Liquid Propane - ft
3
/hr
1/2 load 134 (3.79) 47.6 (1.32) [4.99] (gal/hr)
Full Load
281 (7.96) 133.57 (2.87) [10.86] (E1/hr)
Required fuel pressure to generator fuel inlet at all load ranges - 10 to 12 inches of water column for liquid propane
gas, 5-7 inches water column for natural gas.
CONTROLS
2-Line Plain Text LCD Display
Simple user interface
for ease of operation
2-Wire start
Allows for easy inverter
control correction
Mode Switch
- Auto
Puts unit in standby mode,
waiting for inverter start
call.
- Off
Stops unit. Power is
removed. Control and
charger still operate.
- Manual/Test (start)
Start with starter control,
unit stays on.
Starter Lock-out
Starter cannot re-engage
until 5 sec. after engine
has stopped.
2.5 Amp Smart Battery Charger Standard
Automatic Voltage Regulator with Overvoltage Protection Standard
Automatic Low Oil Pressure Shutdown Standard
Overspeed Shutdown Standard, 72Hz
High Temperature Shutdown Standard
Overcrank Protection Standard
Safety Fused Standard
* Rating definitions - Standby: Applicable for supplying emergency power for the duration of the charging period. No
overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum
wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine
power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will
decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F). Not for sale in California.
15
KILOWATTS
Generac Power Systems, Inc.
S45 W29290 Hwy. 59, Waukesha, WI 53189
generac.com 1-888-GENERAC (1-888-436-3722)
FEATURES
OHVI
®
ENGINE
The Generac OHVI
®
engine, specically designed for
generator use, provides the reliability to power through
the most severe outages. Engineered and built in the
USA.
EVOLUTION
CONTROLLER
The next generation of intuitive controllers, the Evolution
controller features a multilingual, two-line LCD text
display with color-coded backlit buttons.
CONVENIENT INSTALLATION
Can be installed only 18” from the home, if located
away from doors, windows, and fresh air intakes,
unless otherwise directed by local codes.
*
Total harmonic distortion (THD) less than 2.0%—lower than both IEEE
standards for utility power and published numbers for competitive air-
cooled home standby generators.
Built in the USA using domestic and foreign parts.
RHINOCOAT
Our durable RhinoCoat powder-coat nish helps make
sturdy aluminum enclosures perfect for all weather
conditions. Enclosure is able to withstand 150 mph
winds.
FUEL OPTIONS WITH TOOL-LESS
CONVERSION
The Generac EcoGen runs on LP fuel or natural gas,
and easily converts during installation without the need
for tools.
Nationwide Dealer Service Network
Generac’s commitment to service includes scheduled maintenance programs, warranty assistance and emergency service to ensure that Generac customers
are never left powerless. The largest nationwide dealer network has factory-trained technicians on staff and maintains large inventories of Generac parts,
components and accessories. Find a dealer near you at generac.com.