Installation Guide
Operation
34 Installation Guidelines for Air-Cooled Generators
7.7 — Before Initial Start-Up
NOTE: This unit has been run and tested at the factory prior to shipment and does not require any break-in.
Operating the engine with the oil level below the ADD mark on the dipstick can cause 
engine damage.
NOTE: This unit comes filled with 5W - 30 full synthetic oil from the factory. Check the oil level and add the 
appropriate viscosity and amount if necessary.
7.7.1— Installation Wizard
The insulation wizard comes up the first time the generator is powered, it allows the user to input generator settings 
upon power up. See Figure 7-3. 
The Installation Wizard will start every time power (both AC and DC) are removed and then re-applied.
Figure 7-3. Installation Wizard Menu
*
"Generator"
"AcƟve"
"Install Wizard"
"......."
"AcƟvate me (ENT) or"
"ESC to run in manual"
"NOT ACTIVATED !"
""
"Language" 
"<- XXXXX ->"
"To acƟvate go to"
"www.acƟvategen.com"
"- English +" 
"- Espanol +" 
"- Francois +"
"- Portugues +"
" Fuel SelecƟon" 
"<- XX ->"
Note: Set Fuel Type
"Serial 1234567890"
"PASSCODE xxxxx"
"Wrong Passcode"
"Try Again"
"- LP +"
"- NG +"
"Select Hour (0-23)" 
"Select Minute (0-59)" 
"Select Month (1-12)" 
Note: Set Generator Time
"Select Date (1-31)" 
"Select Year (0-99)"
"XXXXX" 
"XXXXX"
Note: Finishes at status screen
ENTER 
ENTER 
This will only come up the Įrst Ɵme the generator is powered. If ESC is pressed to skip the 
acƟvaƟon process, the baƩĞry must be disconnected to allow acƟvaƟon again and this process 
will reiniƟalize. If power is removed aŌĞr a successful acƟvaƟon, the data is remembered and the 
acƟvaƟon steps are skipped. 
ENTER 
3sec delay 
ESCAPE 
ENTER 
wrong entry 
IF NOT YET ACTIVATED 
ENTER 
Note1: Language only shows up 
Įƌst Ɵme it is powered unless 
enter is pressed to skip through 
the install wizard 
Note1: Can run in MANUAL only if 
NOT ACTIVATED 
Note2: Must disconnect baƩĞry to 
allow acƟvaƟon again 