Use and Care Manual
 12 
Maintenance
Use battery charger plug to keep the battery charged and ready for 
use. Battery charging should be done in a dry location.
1.  Plug charger into “Battery Charger Input” jack, located on the 
control panel. Plug wall receptacle end of the battery charger 
into a 120 Volt AC wall outlet.
2.  Unplug battery charger from wall outlet and control panel jack 
when generator is going to be in use.
NOTE:
Do not use the battery charger for more than 48 hours at one 
charge.
Figure 13 - Battery Charger Jack
BATTERY
CHARGER
INPUT
3.1  PERFORMING SCHEDULED MAINTENANCE
It is important to perform service as specified in the Maintenance 
Schedule for proper generator operation, and to ensure that the 
generator complies with the applicable emission standards for the 
duration of its useful life. Service and repairs may be performed by 
any capable person or repair shop. Additionally, emissions critical 
maintenance must be performed as scheduled in order for the 
Emissions Warranty to be valid. Emissions critical maintenance 
consists of servicing the air filter and spark plugs in accordance 
with the Maintenance Schedule. 
3.2 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required 
when operating in adverse conditions noted below.
Check Oil Level  At Each Use
Change Oil ‡  *Every 100 hours or Every Season
Check Valve Clearance  ***Every Season
Service Air Filter  ** Every 200 hours or Every Season
Replace Spark Plug  Every Season
‡  Change oil after first 30 hours of operation then every season.
*  Change oil and oil filter every month when operating under heavy load or in high 
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter 
parts if they cannot be adequately cleaned.
***   Check valve clearance and adjust if necessary after first 50 hours of 
operation and every 100 hours thereafter.
3.3 PRODUCT SPECIFICATIONS
3.3.1 GENERATOR SPECIFICATIONS
Rated Power ...............................................................5.5/6.5/7.5 kW**
Surge Power .......................................................6.875/8.125/9.375 kW
Rated AC Voltage ......................................................................120/240
Rated AC Load
 Current @ 240V (5.5/6.5/7.5 kW) ..................22.9/27.1/31.3 Amps**
 Current @ 120V (5.5/6.5/7.5 kW) ..................45.8/54.2/62.5 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................Single Phase
** Operating Temperature Range : -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. 
F). When operated above 25 deg. C (77 deg. F) there may be a decrease in 
power.
** Maximum wattage and current are subject to, and limited by, such factors 
as fuel Btu content, ambient temperature, altitude, engine condition, etc.. 
Maximum power decreases about 3.5% for each 1,000 feet above sea level; 
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) 
ambient temperature.
3.3.2 ENGINE SPECIFICATIONS
5.5/6.5kW
Displacement .............................................................................. 389  cc
Spark Plug Type ................................ NHSP LDF7TC or Champion N9YC
Spark Plug Part No. .......................................................... 0G84420101
Spark Plug Gap .............................0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity ..........................................25.6 L (6.77 U.S. gallons)
Oil Type.................. See Chart in "Before Starting the Generator" Section
Oil Capacity .................................................................1.0 L (1.06 Qts.)
Run Time at 50% Load .............................................................10 Hours
7.5 kW
Displacement ...............................................................................420cc
Spark Plug Type ................................ Champion N9YC or NHSP LDF7TC
Spark Plug Part No. .......................................................... 0G84420101
Spark Plug Gap .............................0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity ............................................28.4 L (7.5 U.S. gallons)
Oil Type.................. See Chart in "Before Starting the Generator" Section
Oil Capacity .......................................................... 1.0 Liters (1.06 Qts.)
Run Time (50% Load) ..............................................................12 Hours
3.4 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been 
subjected to operator abuse or negligence. To receive full value 
from the warranty, the operator must maintain the generator as 
instructed in this manual.
Some adjustments will need to be made periodically to properly 
maintain the generator.
All adjustments in the Maintenance section of this manual should 
be made at least once each season. Follow the requirements in the 
"Maintenance Schedule".
NOTE:
Once a year replace the spark plug and replace the air filter. 
A new spark plug and clean air filter assure proper fuel-air 
mixture and help the engine run better and last longer.