Full Product Manual
Table Of Contents
- Owner's Manual
- Table of Contents
- INTRODUCTION
- READ THIS MANUAL THOROUGHLY
- SAFETY RULES
- General Information
- Operation
- 2.1 KNOW THE GENERATOR
- 2.2 HOURMETER
- 2.3 CONNECTION PLUGS
- 2.4 HOW TO USE THE GENERATOR
- 2.5 DON’T OVERLOAD THE GENERATOR
- 2.6 WATTAGE REFERENCE GUIDE
- 2.7 BEFORE STARTING THE GENERATOR
- 2.8 STARTING PULL START ENGINES
- 2.9 STARTING ELECTRIC START ENGINES
- 2.10 STOPPING THE ENGINE
- 2.11 LOW OIL LEVEL SHUTDOWN SYSTEM
- 2.12 CHARGING THE BATTERY (ELECTRIC START UNITS ONLY)
- Maintenance
- Troubleshooting
- Notes
- Manual Part No. 0K0172
- Manual del propietario
- Índice
- INTRODUCCIÓN
- LEA ESTE MANUAL MINUCIOSAMENTE
- REGLAS DE SEGURIDAD
- Información general
- Funcionamiento
- 2.1 CONOZCA EL GENERADOR
- 2.2 HORÓMETRO
- 2.3 ENCHUFES DE CONEXIÓN
- 2.4 CÓMO USAR EL GENERADOR
- 2.5 NO SOBRECARGUE EL GENERADOR
- 2.6 GUÍA DE REFERENCIA DE POTENCIA EN WATTS
- 2.7 ANTES DE ARRANCAR EL GENERADOR
- 2.8 ARRANQUE DE MOTORES CON CABLE DE ARRANQUE
- 2.9 ARRANQUE DE MOTORES CON ARRANQUE ELÉCTRICO
- 2.10 PARADA DEL MOTOR
- 2.11 SISTEMA DE APAGADO POR NIVEL DE ACEITE BAJO
- 2.12 CARGA DE LA BATERÍA (UNIDADES CON ARRANQUE ELÉCTRICO SOLAMENTE)
- Mantenimiento
- Resolución de problemas
- Notas
- Manual Parte No. 0K0172
- Manuel d'entretien
- Table des matières
- INTRODUCTION
- LIRE ATTENTIVEMENT CE MANUEL
- RÈGLES DE SÉCURITÉ
- Informations générales
- Fonctionnement
- 2.1 CONNAÎTRE LE GÉNÉRATEUR
- 2.2 HOROMÈTRE
- 2.3 PRISES DE CONNEXION
- 2.4 COMMENT UTILISER LA GÉNÉRATRICE
- 2.5 NE PAS SURCHARGER LA GÉNÉRATRICE
- 2.6 GUIDE DE RÉFÉRENCE DE WATTAGE
- 2.7 AVANT DE DÉMARRER LA GÉNÉRATRICE
- 2.8 DÉMARRER LES MOTEURS À DÉMARRAGE MANUEL
- 2.9 DÉMARRER LES MOTEUR À DÉMARRAGE ÉLECTRIQUE
- 2.10 ARRÊTER LE MOTEUR
- 2.11 SYSTÈME D'ARRÊT DE NIVEAU BAS D'HUILE
- 2.12 CHARGER LA BATTERIE (APPAREILS À DÉMARRAGE ÉLECTRIQUE SEULEMENT)
- Entretien
- Dépannage
- Remarques
- Manuel, référence 0K0172

10
Never light a cigarette or smoke when filling
the fuel tank. Gasoline is highly FLAMMABLE
and its vapors are EXPLOSIVE. Never permit
smoking, open flames, sparks or heat in the
vicinity while handling gasoline.
1. Use regular UNLEADED gasoline with the generator engine. Do
not use any gasoline with more than 10% added ethanol. Do
not use E85 gasoline. Do not mix oil with gasoline.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add unleaded regular gasoline to fuel tank. Be careful
not to overfill (Figure 9).
4. Install fuel cap and wipe up any spilled gasoline.
Figure 9 - Fuel Tank
DO NOT Fill Above Lip
Fuel
Fuel Tank
IMPORTANT: It is important to prevent gum deposits from forming
in fuel system parts such as the carburetor, fuel hose or tank
during storage. Alcohol-blended fuels (called gasohol, ethanol
or methanol) can attract moisture, which leads to separation and
formation of acids during storage. Acidic gas can damage the fuel
system of an engine while in storage. To avoid engine problems,
the fuel system should be emptied before storage of 30 days or
longer. See the "Storage" section. Never use engine or carburetor
cleaner products in the fuel tank as permanent damage may occur.
2.8 STARTING PULL START ENGINES
Never start or stop engine with electrical
devices plugged into the receptacles AND
devices turned on.
1. Unplug all electrical loads from the unit's receptacles before
starting the engine.
2. Make sure the unit is in a level position (not to exceed 15° in
any direction).
3. OPEN the Fuel Shut-off Valve (Figure 10).
4. Turn engine RUN/STOP switch to ON position (Figure 11).
5. Slide engine choke to the LEFT to FULL CHOKE position
(Figure 12).
6. To start engine, firmly grasp the recoil handle and pull slowly
until increased resistance is felt. Pull rapidly up and away.
7. When engine starts, move choke knob to 1/2-CHOKE position
until engine runs smoothly and then fully into RUN position.
If engine falters, move choke back out to 1/2-CHOKE position
until engine runs smoothly and then to RUN position.
NOTE:
If engine fires, but does not continue to run, move choke lever
to FULL CHOKE and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against
overload with push-to-reset-type circuit breakers. If amperage
rating of any circuit breaker is exceeded, that breaker opens and
electrical output to that receptacle is lost. Read “Don’t Overload the
Generator” carefully.
Figure 10 - Fuel Shut-off Valve
Figure 11 - Engine ON/OFF Switch
Operation