TM WATTS TM Portable Generator Owner's Manual Call: Generac Generator Help Helpline M-F 8-5 CT Questions? is just- 1-800-270-1408 a moment away! Web: www.generac-portables.com or www.briggsandstratton.com Model No. 1647-0 (8,000 Watt AC Generator) Manual No.
TABLE OF CONTENTS Safety Rules.................................. Know Your Generator ........................... Assembly .................................... Operation .................................. Maintenance.................................. SAFETY 2-4 5 6-7 8-I1 12 Storage...................................... Troubleshooting ............................... Notes ....................................... Schematic/Wiring Diagram .................... Replacement Parts...........................
DANGER Operate generator ONLY , WARNING WHEN outdoors. ADDING FUEL Keep at least 2 feet of clearance on all sides of generator for adequate ventilation. Turn generator OFF and let it cool at least 2 minutes before removing gas cap. Loosen cap slowly to relieve pressure in tanlc DO NOT operate generator insideany buildingor enclosure, includingthe generator compartment of a recreationalvehicle(RV). Fill fuel tank outdoors. DO NOT overfill tank.Allow spacefor fuel expansion.
CAUTION WARNING See"Don't Overload Generator" on page I I. Start generator and let engine stabilize before connecting electrical loads. ;ENERATOR Connect electrical loads in OFF position, then turn ON for operation. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. Turn electrical loads OFF and disconnect from generator before stopping generator. , WARNING CAUTION Use generator only for intended uses. DO NOT touch hot surfaces.
KNOWYOUR GENERATOR Read this owner's manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Fuel Tank Circuit OnlOff Choke Lever Breakers (AC) \ Recoil Starter .
ASSEMBLY INSTALL Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel. NOTE: Wheel kit is not intendedfor over-the-road use. Generator From • Neddle-nose pliers InstallWheel Carton • Set the palteted carton on a rigid flat surface. • Lift carton off the generator. Placegenerator on a hard flat surface. 2.
9. Withwheels on,secure supportlegassembly tocradle with20mmlongcapscrews, flatwashers, andlock washers. 10.Checkeachfastener to ensureit issecure andtires areinflatedbetween 15-40PSI. 4. Connect red battery cable from engine starter switch to positive (+) terminal on battery with bolt, washer and nut (Figure 2). 5. Connect black battery cable to negative (-) terminal on battery with bolt, washer and nut (Figure 2). INSTALLING 6.
USING System THE GENERATOR OPERATING THE G EN ERATO R Ground CAUTION The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to theAC neutral wire (the neutral is bonded to the generator frame). See"Don't Overload Generator" on page I I. Start generator and let engine stabilize before connecting electrical loads.
_, • DO NOT connect 240Volt loads to 120Volt receptacles. DANGER • DO NOT connect 3-phase loads to generator. • DO NOT connect 50 Hz loads to generator. • DO NOT OVERLOADTHE GENERATOR. See "Don't Overload Generator" on page 1I. Operate Stopping the Engine Unplug all electrical loads from generator panel receptacles.NEVER start or stop engine with electrical devices plugged in and turned ON. 2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.
Usethisreceptacle to operate240VoltAC,60Hz,single phase loadsrequiring upto 8,000watts(8.0kW)ofpower. Theoutletis protected bya35Amppush-to-reset circuit breaker. _ire 120/240 Volt AC, 30 Amp, Cord Set Locking NEMA L5-30 Neutral 120V Receptacle Use a N EMA LI4-30 plug with this receptacle. Connect a 4-wire cord set rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 6).You can use the same 4-wire cord if you )lan to run a 120Volt load.
DON'T OVERLOAD G EN ERATO R You must make sure your generator cansupply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: I. Select the itemsyou wilt power at the same time. 3.
SPECIFICATIONS NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water wilt be retained in voidsand cracks of Maximum SurgeWatts ................ I 0,000 watts Continuous Wattage Capacity ........... 8,000 watts Power Factor .............................. 1.0 Rated Maximum Continuous AC Load Current: At 120Volts ....................... At 240 Volts .......................
STO RAG E Engine See The generator should be started at least once every seven claysand allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days,use the following guidelines to prepare it for Other Storage • Clean the generator as outlined in"Generator Storage owner's manual for instructions.
TROUBLESHOOTING Problem Cause Correction I. I. Reset circuit breaker. One of the circuit breakers is open. No AC output is available, but generator is running. 2. Fault in generator. 2. Contact Authorized service facility. 3. Poor connection cord set. 3. Check and repair. 4. Connected 4. Connect I. Short circuit 2. Generator 3. Shorted generator or defective device is bad. another device that is in good condition.
NOTES I IS
SCHEMATIC 66 77 FUSE lO 77 AHp 13 _ J _2_ra EXCITATION COIL qk CAPACITDR _hYST_ POWER _INDING _ 8 _i ENG IGNITIDN IIA I 16 B POWER XINDING BLK BLU
WIRING DIAGRAM I 17
g--s EXPLODEDVIEW- MAIN UNIT 6 \ 10 / 61 \_ TO STARTER \_TO + TERMINAL ON BAWERY 5 72 18 / 25 52 13 55 18 s2_ 19 55 51 / / 11 26 25 56 77 / 54 46 65 57 ,mira 18
2- _r3 PARTS LISTItem I 2 3 4 5 6 7 8 9 10 II 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 30 31 32 34 35 36 37 38 39 43 44 45 46 47 48 49 Part # NSP BI89039GS 877304GS 77816GS 93826GS 92982GS 84363GS 48031CGS 30340GS 193633GS 84135GS 83465GS 96832GS 23152GS 22237GS 22241GS 75246GS 55934GGS J93074GS 189302AGS 38353GS 22145GS B4986GS 26850GS 49820GS 187104GS 39287GS B85586GS 84605GS 189051GS 82153GS 73054GS 87680GS 45757GS 49813GS 1955362|GS 192980GS 52856GS 62265GS 27482GS 42907GS 22131GS 52618GS 4
2 ¸ _r3 EXPLODEDVIEWAND PARTS LIST-WHEEL KIT 10 4 / Item I 2 3 4 5 6 7 8 9 10 II Part # 191267JGS B4966GS 191265GS 22247GS 191413GS 22145GS 22413GS 39253GS 22129GS B189085GS 192432GS Description AXLE WHEEL E_RING WASHER VIBE MOUNT, with Washer WASHER SCREW SCREW WASHER, Lock LEG,Support NUT, Lock / 20
2 ¸ _rs EXPLODED VIEW AND PARTS LIST- 17 CONTROL PANEL k lO 18 10 8 17 Item I 2 3 4 5 6 7 8 9 I0 II 12 13 14 15 Part # BB4461AGS 23897GS 49226GS 91526GS 78653GS 82881GS B4262GS 75207GS 75207NGS 75207AGS 68759GS 23365GS 68868GS 43437GS 51715GS Description PANEL,Control WASHER WASHER, Lock SCREW SWITCH WASHER, Lock OUTLET, 50A, 240V BREAKER,Circuit BREAKER,Circuit BREAKER,Circuit OUTLET, 20A, 120V WASHER OUTLET, 30A, 120V Locking OUTLET, 30A, 120V/240V Locking NUT Item 16 17 18 19 20 21 22 23
2 ¸ _r3 EXPLODED VI EW AND PARTS LIST - ALTERNATOR 12 9 17 7 3 16 5 15 Item I 2 3 4 5 6 7 8 9 II 12 14 15 16 17 18 19 Part # B4906GS B4907GS B4908GS B4909GS B4910GS 187049GS B4912GS B4913GS B4914GS B4916GS 191297GS B4919GS B4920GS 49820GS 188928GS 22473GS 49813GS Description SHIELD, Front GRID, Front BOLT,Shaft Stay BOLT,Stay ASSY,Housing PLUG, Domed COVER, Blind End COVER,Top Black CAPACITOR CAPACITOR, Diode +Varistor + EMC ASSY,Rotor (Includes Item I I) SCREW SCREW NUT, Lock CONNECTOR, 6-Pin
GENERAC PORTABLE PRODUCTS OWNER EQUIPMENT WARRANTY POLICY LIMITED WARRANTY "Generac Portable Products is a licensedtrademark of Briggs & Stratton Power Products. Briggs & Stratton Power Products will repair or replace, free of charge, any part, or parts of the equipment** that are defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser.
TABLA DE CONTENIDOS INSTRUCCIONES ReglasDe Seguridad .............................. Conozca Su Generador .............................. Ensamblaje...................................... Funcionamiento .................................. Mantenimiento ..................................... AImacenamiento .................................... 24-26 27 28-29 30-33 34 35 Diagnosticos De Averfas .............................. Garantia ..........................................
PELIGRO ADVERTENCIA Opere el generador SOLAMENTE al aire libre. CUANDO Mantenga al menos 2 pies de espacio libre alrededor del generador, para la adecuada ventilaci6n. AI_IADA COMBUSTIBLE Apague el generador (posici6n OFF) y d6jelo enfriar al menos pot 2 minutos antes de remover la tapa de la gasolina.Afloje la tapa lentamente para dejar que la presi6n salgadel tanque.
PRECAUCION ADVERTENCIA Vea "No sobrecargue generador" en la p_gina 33. Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el/actricas. ;ENERADOR Conecte las cargas el_ctricas en la posici6n de apagado (OFF), luego encienda (ON) para su operaci6n. Siempre desconecte el alambre de la bujla y col6quelo donde no pueda entrar en contacto con la bujla. Apague (OFF) las cargas el_ctricas y desconSctelas del generador antes de parar el generador.
CONOZCA SU GENERADOR Lea este manual de| propietario y |as reg|as de seguridad antes de operar su generador. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
MONTAJE INSTALE Su generador requiere de cierto ensamble y estar_ listo para ser usado despu_s de haberle dado un servicio adecuado con el aceite y el combustible recomendados. IMPORTANTE: ser el Generador en DE RUEDAS EsteJuego de Ruedas no ha sidodiseSado para _a carretera, Para instalarsu Juego de Ruedas,usted necesitar_ las siguientes herramientas: Si tiene problemas con el montaje de su generador, por favor Ilame a la Lfnea de Ayuda del Generador al 1-800-270-1408.
9. Con las ruedas instaladas, ahora puede incEnar el extremo 4. del generador e instalar la pata de soporte utilizando dos tornillos prisioneros M8 x 20mm, arandela de seguridad, y arandela plana. 5. 10. Verifique que todas las piezas est_n apretadas y las Ilantas est_n infladas con aire entre 15-40 PSL INSTALACION 6. DEL SOPORTEY Conecte el cable rojo de la baterta del interruptor de arranque del motor al terminal positivo (+) de la bateria con cerroio, la arandela y la tuercas (Figura I I).
H USO DEL GENERADOR Tierra del Sistema OPERANDO EL GENERADOR PRECAUCION El generador dispone de una conexi6n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema est_ conectada al cable de CA neutro que,a su vez, est_ conectado al bastidor del generador. Vea "No sobrecargue generador" en la p_gina 33. Enciendasu generador y deje clue el motor se estabilice antes de conectar las ¢argas el_ctricas.
NO CONECTE cargas de 50 Hz al generador. NO SOBRECARGUE EL GENERADOR.Vea SobrecargueGenerador" en la p_gina 33. Parado 1. 2. PELIGRO "No Del Motor Desconecte todas las cargas el_ctricas de los tomacorrientes del panel del generador. NUNCA de arranque o detenga el motor con todos los dispositivos el_ctricos conectados y encendidos.
Utiliceestetomacorriente paraoperar cargas el_ctricas de 120/240 Voltios AC,60Hz,querequieran hasta 8,000 vatios (8.0kW)a240Voltios depotencia. 120/240 Voltios AC, 30 Amp, mr i| Juego de Cable de 3 Alambres NEMA L5-30 Recept_culo de Seguridad i Use un tapbn NEMA LI4_30 con este recept_culo. Conecte un juego de cable de 4 alambres, clasificado como 250Voltios AC a 30Amps (o mayor) (Figura 15).Usted puede usar el mismo cable de 4-alambres si planea trabajar con una carga de 120Voltios.
NO SOBRECARGUE GENERADOR EL 4. Conecte y encienda la pr6xima carga. 5. De nuevo, permita que el generador se estabilice. 6. Repita los pasos4 y 5 para cada carga adicional que usted tenga. NUNCA a5adamgs cargas sobre la capacidad del generador. Tome una atenci6n especial en considerar lascargas de corriente seg6n la capacidaddel generador, como se describe arriba.
ESPECIFICAClONES Potencia M_xima ................... Potencia de Sobretensi6n Voltaie Nominal 10,000Vatios .............. Corriente M_xima a 240Voltios Corriente M_xima a 120Voltios ............... (8.0 kW) 120/240 Voltios ............... 66.6 Amperios 33.3 Amperios Frecuencia Nominal ...................... Fase ...................................... Tanque del Combustible (I0.0 kW) 8,000Vatios AC .......................
ALMACENAMIENTO Almacenando El generador deber_ ser encendidoal menos una vez cadasiete dfas y deber_ dejarlo funcionar al menos durante 30 minutos. Si no puede hacer esto y debe almacenar la unidad por m_s de 30 dfas,siga las siguientes instruccionespara preparar su unidad para almacenamiento. Consulte el manual del propietario del motor para las instrucciones de cbmo preparar adecuadamente el motor para su almacenamiento.
POLJTICA PARA EL PROPIETARIO DE EQUIPOS GENERAC Efectiva desde el Iro de Enero, 2003 PORTABLE PRODUCTS GARANTIA LIMITADA "Generac Portable Productses una marca registrada licenciada de Briggs& Stratton Power Products. Briggs & Stratton Power Products repararg o sustituirg sin cargo alguno cualquier componente del equipo** que presente defectos de materiales y/o mano de obra.