Ifthe choke lever has been moved to the "Closed"
position to start the engine, gradually move it to the
"Open" position as the enginewarms up.
Attach the nozzle extension to the spray gun. Tighten by
hand (Figure I I).
Select the desired quick connect nozzle and insertit into
the end of the nozzle extension (see "How To Use the
Nozzles").
Disengagethe safety latch on the spraygun.
How to Stop Your Pressure Washer
Move the throttle lever to the "Slow" position.
Move the fuel valve to the "Off" position.
Wait for the engine to idledown.
Move the engine switch to the "Off" position.
Simply shutting off the engine will not release pressure in
the system. Squeeze trigger on the spray gun to
relieve pressure in the hose.
Flow to Use the Nozzles
_ CAUTION! Never exchange nozzles without
lockingthe safety latchon the trigger.
The quick-connect on the nozzle extension allows you to
switch between five different nozzles. The nozzles varythe
spray pattern as shown below (Figure 12).
Follow these instructions to change nozzles:
Engagethe safety latch on the spray gun.
•Putl back the collar on the quick-connect and pult the
current nozzle off. Store the nozzle in the space provided
on the handles storage panel.
NOTE: For a more gentle rinse, select the white 40° or
green 25° nozzle. To scour the surface, select the yellow
15° or red 0° nozzle. To applychemical, select the black
nozzle.
•Putl back on the collar, insertthe new nozzle and release
the collar. Tug on the nozzle to make sure it is securely
in place.
For most effective cleaning,keep the spray nozzle
between B to 24 inchesawayfrom the cleaningsurface. If
you get the spray nozzle too close, you maydamage the
cleaning surface.
Low Pressure
apply
chemical
Black
25 °
High Pressure
White Green Yellow Red
40° 25° 15° 0°
/