The Reliable Ones SEIO Portable Generator Owner's Manual A DANGER[ This generator is designed for outdoor use only, Never use this generator inside any building or enclosure including the generator compartment of a recreational vehicle (RV). Carbon monoxide poisoning, fire and/or an explosion may result.
GeneracPortableProducts SE10000Generator EQUIPMENT SAFETY RULES DESCRIPTION This generator is an engine-driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliance, tool and motor loads. This manual contains information for a generator that operates 120 and/or 240 Volt, single phase, 60Hz devices that require up to 10,000 watts (10.0 kW) of power that pull up to 83.3 Amps at 120 Volts or 41.
GeneracPortableProductsSE10000 Generator GROUNDING THE GENERATOR • The generator produces a very powerful voltage that can cause serious injury or death by electrocution. Never touch bare wires or receptacles. Never permit a child or any unqualified person to operate the generator. The National Electric Code requires the frame and external electrically conductive parts of the generator be properly connected to approved earth ground. Local electrical codes may also require proper grounding of the unit.
GeneracPortableProducts SE10000Generator Yourgeneratorrequiressomeassemblyandis ready foruseafterit hasbeenproperlyservicedwiththe recommended oilandfuel. If you have any problems with the assembly of your generator, please call the generator at 1-800-270-1408. CHECK BATTERY / ATTACH NEGATIVE BATTERY WIRE The battery on the generator is fully charged, sealed and pre-installed except for the negative (black) battery cable.
GeneracPortableProductsSE10000 Generator WHEEL KIT INSTALLATION You will need a 13mm metric box, open end or socket wrench to install this kit. Install Wheel Kit as follows: (Figure 3) 1 Place the bottom of the generator cradle on a flat, even surface. It may help to raise the cradle on temporary blocks. 2. Slide axle through both axle mounting brackets on cradle frame. 3. Slide spacer over each end of axle. 4. Install the wheel. Secure wheel on axle with retaining pin and washer.
GeneracPortableProducts SE10000Generator KNOW YOUR GENERATOR Read this owner's manual and safety rules before operating your generator.
GeneracPortableProductsSE10000 Generator BEFORE STARTING THE GENERATOR can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See "Storage" on page 12. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur.
GeneracPortableProducts SE10000Generator A run engine indoors areas. ,_ IMPORTANT! Do not overload the generator! Do not overload individual panel receptacles! These outlets are protected against overload with push-toreset-type circuit breakers.
GeneracPortableProductsSE10000 Generator Connecting Electrical 120 Volt AC, 20 Amp Receptacle Loads • DO NOT connect 240 Volt loads to 120 Volt Use a NEMA L5-20 plug with this receptacle Connect a 3-wire cord set rated for 125 Volts AC at 20 Amps (or greater) to the plug (Figure 9).
GeneracPortableProducts SE10000Generator Usethisreceptacle to operate120VoltAC,60 Hz, singlephaseloadsrequiringupto 3600watts (3.6kW)ofpowerat 30Amps.Theoutletis protected bya 30Amppush-to-reset circuitbreaker. 240 Volt AC, 50 Amp Receptacle Use a NEMA 14-50 plug with this receptacle. Connect a 4-wire cord set rated for 250 Volts at 50 Amps to the plug (Figure 12) 120/240 Volt AC, 30 Amp Receptacle Use a NEMA L14-30 plug with this receptacle.
GeneracPortableProductsSE10000 Generator DON'T OVERLOAD GENERATOR THE • If wattage is not given, multiply volts times ampere rating to determine watts (volts x amps = watts). • Some electric motors, such as induction types, require about three times more watts of power for starting than for running. This power surge lasts only seconds when starting such motors.
GeneracPortableProductsSE10000Generator GENERAL MAINTENANCE RECOMMENDATIONS more than 30 days, use the following guidelines to prepare it for storage. Generator The Owner/Operator is responsible for making sure that alt periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. Never operate a damaged or defective generator. Storage • Clean the generator as outlined in "To Clean the Generator.
GeneracPortableProductsSEIO000Generator NOTES / 13
GeneracPortableProducts SE10000Generator TROUBLESHOOTING Problem Cause Engine is running, but no AC output is available. 1. Circuit breaker is open. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator, Engine runs good but bogs down when loads are connected. 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too stow. 4. Shorted generator circuit. Engine will not start; or starts and runs rough. 1. Dirty air cleaner, 2.
GeneracPortableProductsSEIO000Generator NOTES / 15
ID]_LF_i_]_ SCHEMATIC GeneracPortableProducts SEIO000Generator DIAGRAM EXCITATION _IL CAPACITDR 44& / 16
GeneracPortableProductsSEIO000GeneratorID_'! _ WIRING DIAGRAM 45A ¢5_ KEY SWITCH TERMINAL _LDCK CaNTRaL PANEL GON GRDUND BEARING TB REAR CARR[ER SUPPLrE_ _ATTERY / 17
Generac Portable Products SEIO000 Generator I ?j/- I GENERATOR EXPLODED VIEW 10 / 7"\\\\\ 5 54 I \ 65 55 2 56 62 61 14 57 15 Detail of Battery Troy 62 ,b 50 65 \\_20 / 18 \ 59 15
GeneracPortableProductsSE10000 Generatorl/! I m GENERATOR Item 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Pa_ # Qty NSP 1 BB4509 1 A77304 2 BB4811 1 80270 1 78299 1 B4325 1 38353 6 78831B 4 B1696 1 AB4426 1 83465 4 23152 7 22237 20 22241 10 22746 4 22131 8 BB5117 1 B4425 1 195-53621 1 38750 1 B4502 1 22145 2 26850 3 20566 1 B4986 1 92982 1 B4865 1 B4866 1 78817 1 77816 2 B4826 1 B4824 1 79552 1 73054 1 B4268 1 BB4481 1 20441 4 B4489 1 PART
Generac Portable Products SE10000 Generator I j/_ I ALTERNATOR EXPLODED VIEW AND PARTS LIST 15 10 7 \ \ 6 \ \\\\\ 15 Item 1 2 3 4 5 6 7 8 9 Part # B4906 B4907 B4908 B4909 B4910 B4911 B4912 B4913 B4914 Qty 1 2 1 4 1 1 1 1 2 Description SHIELD, Front GRID, Front BOLT, Shaft Stay STAY BOLT, M8 x 30 ASSEMBLY, Housing CAP COVER, Blind End COVER, Top Black CAPACITOR, 25mF 450V / 2O Item 10 11 Part # B4915 B4916 Qty 1 1 12 13 14 15 16 B4917 B4918 B4919 B4920 49820 1 1 2 8 1 Description BEARI
GeneracPortableProductsSE10000 GeneratorIll I m CONTROL PANEL EXPLODED VIEW AND PARTS LIST 27 2B 24 23 \ 24 \ 23 2 10 5 25 9 8 / 17 18 9 \ 8 15 3 Item 1 2 3 4 5 6 7 Pa_ # BB4504 23897 91526 49226 75207 23365 68759 Qty 1 5 4 5 3 12 1 8 9 10 11 12 13 38150 22264 51715 75207A 74190 68868 12 12 12 2 1 1 14 15 B4445 B4262 2 1 Description PANEL, Control FLAT WASHER, #10 - M5 PPHMS, M5- ,08 x 12mm LOCK WASHER, M5 CIRCUIT BREAKER, 20 Amp WASHER, #8 Shakeproof OUTLET, 120V, 20 Amp Duplex FLA
Generac Portable Products SE10000 Generator I ? j/_ I WHEEL KIT EXPLODED VIEW AND PARTS LIST 1@ 13 Item 1 2 3 4 5 6 7 8 9 lO 11 12 13 14 Pa_ # 93393B 39287 52858 93394 27007 22145 42909 39253 93693B 89635 89742 22247 87005 22129 Qty 1 4 5 1 1 3 1 2 1 2 2 2 2 2 Description HANDLE HHCS, M8 - 125 x 45mm NUT, Locking M8 - 1 25 LEG, Mounting Support MOUNT, Vibration FLAT WASHER, 5/16 - M8 HHCS, M8 - 1.25 x 30mm HHCS, M8 - 1.
GeneracPortableProductsSEIO000Generator NOTES / 23
LIMITED WARRANTY FOR OVERHEAD VALVE V-TWIN ENGINE-DRIVEN PORTABLE GENERATORS GENERAC PORTABLE PRODUCTS (hereafter referred to as the COMPANY) warrants to the original purchaser that all components originally equipped with the generator, excluding the engine, for its portable generator will be free from defects in materials or workmanship for the items and period set forth below from the date of original purchase.