Manual
Generac Pori:ableProducts7,500F..XLGenerator
8-WssO dSst
Use this receptacleto operate 120Volt AC, 60 Hz, single
phase loads requiring up to 3,600 w_cs (3.6 EW) of power
•t 30Amps. The outlet is protected by a 30 Amp
push-to-reset circuit breaker.
120/240 Volt AC, 30 Amp Locking
Receptacle
Use • NEMA LI4-30 plugwith this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps
(or greater). You c_n use the same 4-wire cord if you piton
to run a 120 Volt load (Figure 14).
4Wte od 8el
< ...................£@V ................>
This receptacle powers 120 Volt AC, single phase, 60 Hz
loads requiring up to 3,600 w_cs of power (3.6 IcW). Or it
will operate 240 Volt AC, single phase, 60Hz loads up to
7,200 w_cs (7.2 IcVV).This outlet is protected by • 30 Amp
push-to-reset circuit breaker.
120/240 Volt AC, 50 Amp Receptacle
Use • NEMA 14-50 plug with this receptacle. Connect
4-wire cord set rated for 240 Volt AC Io_ds _t 50 Amps to
the plug (Figure 15).
i
Y (Hot)
W (Neutral)
X (Hot)
NEMA 14-50
Use this receptacle to operate 240 Volt AC, 60 Hz, single
phase loads requiring up to 7,500 w_cs (7.5 kVV) of power.
_{_ CAUTION! Although this outlet states it has a
240 Volt 50 Amp rating (up to 12,500 watts), the
generator is only rated for 7,500 watts. Powering
loads that exceed the w_age/amperage cap_city of
the generator c_n damzge it or c_use serious
fnjurfes.
/