Manual

Generac Portable Products 3000 Watt Generator
The generator produces a very powerful voltage that can
causeserious injuryor death by electrocution. Never
touch bare wires or receptacles. Never permit a child
or any unqualified person to operate the generator.
Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet
are wet Death or serious injuryfrom electrocution may
result.
Use a ground fault circuit interrupter (GFCI) in anydamp
or highly conductive area (such as metal decking or steel
work).
Never use worn, bare, frayed or otherwise damaged
electrical cords with the generator. Death, serious injury
and property damage from electrical shock may result.
Gasoline is highly FLAMMABLE and its vapors
are EXPLOSIVE. Never allow smoking, open
flames, sparks or heat in the vicinity while
handling gasoline. Avoid spilling gasoline on a hot
engine. Comply with all laws regulating storage and
handling of gasoline.
Do Not overfill the fuel tank. Always allow room for
fuel expansion. If tank is overfllled, fuel can overflow
onto a hot engine and cause a FIRE or an
EXPLOSION.
Never store a generator with fuel in the tank where
gasoline vapors might reach an open flame, spark or pilot
light (as on a furnace, water heater, clothes dryer). FIRE
or an EXPLOSION may result.
The unit requires an adequateflow of cooling air for its
continued proper operation. Never operate the unit
insideany room or enclosure where the free flow of
cooling air intoand out of the unit might be obstructed.
Allow at least2 feet of clearanceon all sides of generator,
even while operating unit outdoors, or you could damage
the unit
Never start, or stop the unit with electrical loads
connected to receptacles with the connected devices
turned ON. Start the engine and let it stabilize before
connecting any electrical loads. Disconnect all electrical
loads before shutting down the generator.
Do Not insertanyobject through cooling slots of the
engine.You could damagethe unit or injureyourself.
Never operate the generator:
in rain; in any enclosedcompartment;when connected
electricaldevices overheat; if electrical output islost;if
engine or generator sparks; ifflame or smoke is
observed while unit isrunning; ifunit vibrates
excessively.
GROUNDING THE
G EN ERATO R
The National ElectricalCode requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure I).
Generally, connecting a No. 12AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth-driven copper or brassgrounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.
Properly grounding the generator helps prevent electrical
shock ifa ground fault condition exists inthe generator or
in connected electrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.
/
3