SDS
Page 3 of 6     MSDS – GENERAC SAE 30 MOTOR OIL 
Empty containers may contain residues. 
-------------------------------------------------------------------------------------------------------------------- 
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 
-------------------------------------------------------------------------------------------------------------------- 
Exposure Guidelines 
A: General Product Information 
If oil mists are generated, observe the OSHA exposure limit of 5 mg/m3. The following are recommended 
exposure limits for hydrogen sulfide: OSHA PEL 8H TWA 10ppm; 14mg/m3, Ceiling 20 ppm and ACGIH 
8H TWA 10ppm; 14mg/m3. 
B: Component Exposure Limits 
No information is available. 
Engineering Controls 
Use general ventilation and use local exhaust, where possible, in confined or enclosed spaces. If product is 
heated above 70 C (155 F) in the presence of water, hydrogen sulfide vapors may be released. Ventilation 
should be sufficient to keep hydrogen sulfide levels below recommended exposure limits. 
PERSONAL PROTECTIVE EQUIPMENT 
Personal Protective Equipment: Eyes/Face 
Wear safety glasses. Wear chemical goggles or face shield if splash or mist occurs. 
Personal Protective Equipment: Skin 
Use impervious gloves for prolonged contact. Wear oil-impervious garments if contact is unavoidable. 
Personal Protective Equipment: Respiratory 
If mist is generated (heating, spraying) and engineering controls are not sufficient, wear approved organic 
vapor respirator suitable for oil mist. 
Personal Protective Equipment: General 
Use good hygiene when handling petroleum product. Launder contaminated clothing before reuse. 
Excessive misting may cause slippery floors - wear appropriate footwear. Eye wash fountains are 
recommended. 
-------------------------------------------------------------------------------------------------------------------- 
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 
-------------------------------------------------------------------------------------------------------------------- 
Physical State: Viscous liquid 
Vapor Density: > 1 (air =1.0) 
Vapor Pressure: Not available 
Evaporation rate: Not available 
Boiling Point: Not available 
Melting/Freezing Point: Not available 
pH: Not available 
Coefficient of Water/Oil Distribution: Not available 
Solubility in Water: Insoluble 
Specific Gravity: 0.88 
Flashpoint (method): Typical 400°F / 204°C (ASTM D-92) 
Odor: Typical petroleum 
Color: Light amber 