Manual
Problem LED Things to
Check Active Alarm Solution
Check the
STEPPER Contact servicing dealer.
Unit will not start in AUTO with utility RED LEDs/Screen OVERCURRENT
loss. for alarms.
Check the
Unit will not start in AUTO with utility RED LEDs/Screen MISWIRE Contact servicing dealer.
loss. for alarms.
Check the
Unit will not start in AUTO with utility RED LEDs/Screen OVERVOLTAGE Contact servicing dealer.
loss. for alarms.
Yellow LED illuminated in any state.
YELLOW
Check screen
for additional
information.
LOW BATTERY
Clear alarm. From the MAIN menu on
the control panel, navigate to the BAT-
TERY MENU. Contact servicing dealer if
battery is GOOD. Replace battery If
CHECK BATTERY is displayed.
Check screen
BATTERY
Yellow LED illuminated in any state. YELLOW for additional PROBLEM Contact servicing dealer.
information.
YELLOW Check screen CHARGER
Yellow LED illuminated in any state, for additional WARNING Contact servicing dealer
information.
Check screen
Perform SERVICE A maintenance;
Yellow LED illuminated in any state. YELLOW for additional SERVICE A
information, press ENTER to clear.
Check screen
Perform SERVICE B maintenance;
Yellow LED illuminated in any state. YELLOW for additional SERVICE B
information, press ENTER to clear.
Check screen
Yellow LED illuminated in any state. YELLOW for additional Inspect Battery Inspect battery; press ENTER to clear.
information.
30 Automatic Standby Generator Owner's Manual