Manual
3.7.3m 120V GFCI Outlet/15 Amp Breaker (17 & 20 kW Only)
All units are equipped with an external 15 amp, 120 volt GFCI convenience outlet located in the top corner of the compartment.
When the generator is running, in the absence of utility power, this outlet may also be used to power items outside the home such as lights or
power tools. This outlet may also be used when utility power is present by running the generator in manual mode.
This outlet does not provide power if the generator is not running. Do not use this outlet when the generator is in Exercise mode. This outlet is
protected by a 15amp circuit breaker in the side compartment.
3.8 m Alarm Response Procedures
The generator is protected by a series of sensors that will detect an Alarm/Warning condition and alert the owner/operator of the condition via the
Control Panel display. When certain alarm conditions are detected, the generator will shut down.
Alarm/Warning conditions can include (this is not a complete list):
• Low Oil Pressure
• High Engine Temperature
• Low Battery
• Under-voltage
• Exercise Set Error
NOTE:Unless properlytrained to clearandcorrectWarning andAlarmconditions,contactthe nearestAuthorizeddealerorTrained
Technician.
3.9 m Battery Charger
NOTE: The battery charger is integrated into the control module in all models.
The battery charger operates as a "Smart Charger" that ensures:
• Output is continually optimized to promote maximum battery life.
• Charging levels are safe.
NOTE:A warningisdisplayedonthe LCDwhenthe batteryneedsservice.
3.10 Setting the Exercise Timer
Thisgeneratorisequippedwith anexercisetimer.Onceit isset, thegeneratorwillstartandexerciseeverysevendays,onthedayof theweekandat thetimeof day
specified.Duringthis exerciseperiod,theunitrunsfor approximately12minutesandthenshutsdown. Transferof loadsto thegeneratoroutputdoesnotoccurduring
theexercisecycleunlessutilitypowerislost.
Theexercisesettingscanbechangedat anytime via the"EDIT"menu.
If the 12 volt batteryis disconnectedor the fuseremoved,theInstallationWizardwill operateuponpowerrestoration.Theonlydifferenceisthedisplaywillonly
promptthecustomerfor thecurrentTimeandDate.
Theexerciserwill onlyworkintheAUTOmodeandwill notwork unlessthis procedureis performed.The currentdatettimewill needto bereseteverytimethe 12
volt batteryis disconnectedandthenreconnected,and/orwhenthefuse is removed.
Automatic Standby Generator Owner's Manual 17