Manual

2.4 -- Specifications
2.4.1 -- Generator
Model 8kW 11kW 13kW 14kW 15kW 16kW 17kW 20kW
RatedVoltage 240
RatedMaximumLoad
Current(Amps)at240 33.3 45.8 54.2 58.3 62.5 66.6 70.8 83.3
Volts (LP)*
MainCircuitBreaker 35Amp 50Amp 55 Amp 60Amp 60 Amp 65 Amp 65 Amp 100Amp
Phase 1
RatedACFrequency 60 Hz
BatteryRequirement Group26R, 12Voltsand 525 CCA Minimum(GeneracPartNo. 0H3421S
Weight (unitonly in 360/163.3 407/184.6 435/197.3 435/197.3 471/213.6 471/213.6 Steel- 451/204.6
Ibs./kilos) 471/213.6
Aluminum-
437/198.2
Enclosure Steel/
Steel Steel Steel Steel Steel Steel Aluminum
Aluminum
NormalOperating Thisunit istestedin accordancetoUL2200standardswith anoperatingtemperatureof -200F (-29oC) to 122oF (500C). For areaswheretem-
Range peraturesfallbelow32° F (0° C)a coldweatherkit ishighlyrecommended.Whenoperatedabove770F (250C)there maybe a decreasein engine
power.Pleasereferencethe enginespecificationssection.
These generatorsareratedin accordancewith UL2200,SafetyStandardfor StationaryEngine GeneratorAssemblies,andCSA-C22.2No.100-04
Standardfor Motorsand Generators.
* NaturalGas ratingswill dependon specificfuel Btu/joulescontent.Typicalderatesarebetween10-20%off the LP gasrating.
** Circuitsto be movedmustbe protectedby samesizebreaker.For example,a 15 ampcircuitin the mainpanelmustbe a 15 ampcircuitin the transferswitch.
2.4.2 -- Engine
Model 8kW 11kW 13/14/15/16/17kW 20kW
Type of Engine GH-410 GT-530 GT-990 GT-999
Number of Cylinders 1 2 2 2
Displacement 410cc 530cc 992cc 999cc
Cylinder Block Aluminum w/Cast Iron Sleeve
Recommended Spark Plug RC14YC BPR6HS RC14YC RC12YC
Spark Plug Gap 0.76mm (0.030") 0.76mm (0.030") 1.02mm (0.040") 0.76mm (0.030")
Starter 12 VDC
Oil Capacity Including Filter Approx. 1.5 Qts./1.4L Approx. 1.7 Qts./1.6L Approx. 1.9 Qts/1.8L Approx. 1.9 Qts/1.8L
Recommended Oil Filter Part #070185E
Recommended Air Filter Part #0E9371A Part #0E9371A Part #0J8478 Part #0J8478
Engine power is subject to and limited by such factors as fuel Btu/joules content, ambient temperature and altitude. Engine power decreases about 3.5
percent for each 1,000 feet (304.8 meters) above sea level, and also will decrease about 1 percent for each 6° C (10° F) above 15° C (60o F) ambient tem-
perature.
The specification sheet for your generator was included in the documentation provided with the unit at the time of purchase. For additional
copies, consult your local Authorized Service Dealer for your specific generator model.
8 Automatic Standby Generator Owner's Manual