Manual
Figure 2 - Contro/ Pane/ Figure 4 - Generator Contro/s
11. Handle - Pivot and retract for storage. Press the spring-
loadedbuttonto move handles.
12. GasCap- Fuelfill location.
13. FuelGauge- Showsfuel levelin tank.
14. OilFill - Add oil here.
15. Recoil Starter - Useto start enginemanually.
15. Fuel Shut Off- Valve betweenfuel tank and carburetor.
17. Battery Charger Input - This receptacleallowsthe capability
to recharge the 12 volt DC storage battery provided with
the 12 Volt Adaptor Plug Charger which is included in the
Accessory Box. Located behindthe battery charger input is
a 1.50 Amp in-line fuse which is inside the control panelto
protect the batter(electric start only).
18. Battery - Powersthe electric starter (electric start only).
19. Hourmeter - Trackshours of operation.
Figure3 - GeneratorControls
2.2 HOURIVIETER
TheHourmetertrackshoursof operationfor scheduledmaintenance
(Figure5):
Therewill be a"CHGOIL"messageevery100 hours.The message
will flash one hour before and one hour after each 100 hour
interval, providinga two hourwindow to perform service.
This messagewill actually beginflashing at 99 hours and disable
itself at 101 hours again,providing atwo hourwindow to perform
the service.
Every200 hours the "SVC"icon on the lower left hand corner of
the display will flash. The messagewill flash one hourbefore and
onehour aftereach200 hourintervalprovidingatwo hourwindow
to perform service.
Whenthe hour meter is inthe FlashAlert mode, the maintenance
message will always alternate with elapsed time in hours and
tenths. The hours wilt flash four times, then alternate with the
maintenancemessagefourtimes until the meter resets itself.
* 100 hours - CHGOIL-- OilChangeInterval(Every100 hrs)
Note:
The hour glassgraphicwill flash on and off when the engine
is running.This signifiesthat the meter is tracking hours of