Technical Diagram

- 1 PWRcell Inverter - 1 CT Kit (included)
- 6 PV Links
- 2 PWRcell Batteries
This design shows a Generac PWRcell system fully utilizing all
of its DC terminals to the maximum possible. A Protected
Loads Panel in connected to the output of the inverter to
provide backup power for Self-Consumption and/or Islanding
situations..
This configuration is acceptable for use with 200A or larger
utility services.
30A
30A
30A
30A
Power Conversion
PWRcell
TM
Inverter
Generac
PowerCore
Router
Ethernet (CAT5)
50A
AC Grid
Main Distribution
Panel
M
CTs (CAT5)
Protected Loads Panel
200A
40A
Storage
PWRcell Battery
PV Array
PV Optimization
PV Link
TM
Substring Optimizer
REbus
TM
DC nanogrid
Powered by REbus (DC Voltage)
AC Voltage
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION.
*Installer responsible for code compliance.
*Refer to product manuals for additional installation
details and requirements.
Reference Code-
2412-01
Max. Capacity System / Solar + Storage
Page 10 of 11
Part No. A0000521683 Rev. D 03/10/2020
© Generac Power Systems, Inc. All rights reserved
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189