Install Manual

Installing Generac PWRcell Battery
18 Installation Manual for Generac PWRcell Battery
Installing Module Spacer (PWRcell 9 and
PWRcell 15 only)
See Figure 4-11. Module spacers (O) must be installed
on any single module shelf.
O
009933
Figure 4-11. Module Spacer
PWRcell modules and upgrade kits can be obtained by
contacting Generac Customer Service at 1-888-436-
3722 (1-888-GENERAC), or www.generac.com.
NOTE: Kits must be installed by a qualified individual.
Table 5 – Module Spacer Kit
Module Spacer Kit Part Number
Generac PWRcell Spacer Kit APKE00008
To install module spacer:
1. See Figure 4-12. Angle top of spacer (P) under
and behind bracket lip (Q).
P
Q
009934
Figure 4-12. Installing Module Spacer (1 of 3)
2. See
Figure 4-13
. Slide spacer up between brackets.
3. Push bottom of spacer in.
1
2
009935
Figure 4-13. Installing Module Spacer (2 of 3)
4. See Figure 4-14. Secure spacer with two M4X8
SEMS screws and torque to 13 in-lb (1.47 Nm).
009936
Figure 4-14. Installing Module Spacer (3 of 3)
Installing Retention Clips
See Figure 4-15. All front battery modules must be
secured with retention clips (R).
R
009937
Figure 4-15. Retention Clips (1 of 3)