Maintenance
Owner’s Manual for Spark-Ignited Stationary Generators 31
Figure 5-12. Check Accessory/Drive Belt Deflection
Replacing Air Filter Element
Proceed as follows to replace air filter element:
1. See Figure 5-13. Remove nut (B) and bolt (C) from
air filter clamp, and loosen elbow clamp (D) to
release air cleaner.
Figure 5-13. Air Cleaner Cover and Filter Element
2. Remove air filter element (A) and discard.
3. Thoroughly clean elbow of any dust, dirt, or debris.
4. Place new air filter element into elbow clamp.
5. Install elbow clamp over clamping surfaces and
tighten. Install nut and bolt from air filter clamp, and
tighten until snug.
NOTE: Service kits are available from an IASD.
Final Instructions
Proceed as follows if only performing Schedule A mainte-
nance procedures:
1. Install negative battery cable (black) onto negative
battery (-) terminal.
2. Install left and right side access panels. See
Access Panels.
3. See Return To Service.
A Water pump pulley
B Alternator pulley
C Automatic tensioner
010060
C
B
A
010162
B
C
D
A